Emerson Process Management 5300 Marine RADAR User Manual


 
Reference Manual
00809-0100-4530, Rev BA
July 2009
Rosemount 5300 Series
A-32
Spare parts list Probe Model 5301/5302/5303
Model Product Description
5309 Spare probe
Code Signal Output
N Not Applicable
Code Housing Material
N Not Applicable
Code Conduit / Cable Threads
N Not Applicable
Code Operating Temperature and Pressure
(1)
Probe Type
S - 15 psig (-1bar) to 580 psig (40 bar) @ 302 °F (150 °C) All
H High Temp / High Pressure
(2)
:
2940 psi @ 752 °F and 5000 psi @ 100 °F (203 bar @ 400 °C and
345 bar @ 38 °C) according to ANSI Class 2500
3A, 3B, 4A, 4U, 4V, 5A and 5B
P High Pressure
(2)
:
Max 392 °F (200 °C): 3500 psi @ 392 °F and 5000 psi @ 100 °F (243 bar @
200 °C and 345 bar @ 38 °C) according to ANSI Class 2500
3A, 3B, 4A, 5A and 5B
C Cryogenic Temperature
(2)
(3)
-321 °F (-196 °C)
Max 392 °F (200 °C): 3500 psi @ 392 °F and 5000 psi @ 100 °F (243 bar
@ 200 °C and 345 bar @ 38 °C) according to ANSI Class 2500
3A, 3B, 4A, 5A, 5B (only SST)
Code Material of Construction
(4)
: Process
Connection / Probe
Probe Type Valid Operation Temperature and Pressure
1 316 L SST (EN 1.4404) All S, H, P, C
2 Alloy C-276 (UNS N10276). With plate
design if flanged version. Up to class 600,
PN 63 for HTHP/HP probes.
3A, 3B, 4A S, H, P
3 Alloy 400 (UNS N04400). With plate
design if flanged version.
3A, 3B, 4A, 5A, 5B S
7 PTFE covered probe and flange. With
plate design.
4A and 5A S
8 PTFE covered probe. 4A and 5A S
H Alloy C-276 (UNS N10276) process
connection, flange and probe
(5)
3A, 3B, 4A H, P
Code Sealing, O-ring Material (Consult factory for other o-ring materials)
NNone
(6)
V Viton
®
fluoroelastomer
E Ethylene Propylene
K Kalrez
®
6375 perfluoroelastomer
B Buna-N
Code Probe Type Process Connection Probe Lengths
1A Rigid Twin Lead
(7)
Flange / 1.5 in., 2 in.
(7)
Thread Min: 1 ft 4 in. (0.4 m). Max: 9 ft 10 in. (3 m)
2A Flexible Twin Lead with weight
(7)
Flange / 1.5 in., 2 in.
(7)
Thread Min: 3 ft 4 in. (1 m). Max: 164 ft (50 m)
3A Coaxial (for level measurement)
(8)
Flange / 1 in.
(7)
, 1.5 in., 2 in.
(7)
Thread
Min: 1 ft 4 in. (0.4 m). Max: 19 ft 8 in. (6 m)
3B Coaxial, perforated. For level and interface
measurement, or easier cleaning.
Flange / 1 in.
(7)
, 1.5 in., 2 in.
(7)
Thread
Min: 1 ft 4 in. (0.4 m). Max: 19 ft 8 in. (6 m)
4A Rigid Single Lead (8 mm) Flange / 1 in.
(7)
, 1.5 in., 2 in.
(7)
Thread / Tri-Clamp
Min: 1 ft 4 in. (0.4 m). Max: 9 ft 10 in. (3 m)
4B Rigid Single Lead (13 mm)
(9)
Flange / 1 in., 1.5 in., 2 in. Thread
/ Tri-Clamp
Min: 1 ft 4 in. (0.4 m). Max: 14 ft 9 in. (4.5 m)
4U Vapor Single Rigid Probe for 2 in. pipes
(10)
Flange / 1.5 in. Thread Min: 2 ft 5 in. (0.76 m). Max: 13 ft (4 m)