Emerson Process Management 5300 Marine RADAR User Manual


 
Reference Manual
00809-0100-4530, Rev BA
July 2009
Rosemount 5300 Series
F-4
TCL 37 This parameter is used for User Defined probes only. Please
contact Emerson Process Management Service Department
for more information
PROPAGATION_FACTOR 38 This parameter is used for User Defined probes only. Please
contact Emerson Process Management Service Department
for more information
REF_PULSE_AMPL 39 This parameter is used for User Defined probes only. Please
contact Emerson Process Management Service Department
for more information
GEOM_TANK_HEIGHT 40 Tank Height (R)
GEOM_HOLD_OFF_DIST 41 Hold off distance
VAPOR_DC 42 Enter the dielectric constant for the vapor gas in the tank. For
air at 20 degC and atmospherical pressure the vapor DC is
close to 1, but for high pressure/high temperature applications
the DC may increase and affect the accuracy of the
measurement
UPPER_PRODUCT_DC 43 Enter the Upper Product Dielectric Constant (DC) as dielectric
accurate as possible. This value affects the accuracy of the
interface level measurement
LOWER_PRODUCT_DC_RANGE 44 Enter the range of the dielectric constant (DC) for the lower
product in the tank. If you are uncertain about the value for
this parameter or are changing product in the tank on a
regular basis choose Unknown
PRODUCT_DIELEC_RANGE 45 Enter the range of the Product DC for the product in the tank.
If you are uncertain about the value for this parameter or are
changing product in the tank on a regular basis choose
Unknown
MEAS_MODE 46 Select the Measurement Mode to use in the device. Some
modes require software options to be enabled in the device.
You can upgrade the device to enable more software options
DAMP_VALUE 47 Damping value
GEOM_OFFSET_DIST 48 Distance Offset
GEOM_CALIBRATION_DIST 49 Calibration Distance
LCD_SETTINGS 50
LCD_PARAMETERS 51 Parameters to show
LCD_LANGUAGE 52 Language on display
LCD_LENGTH_UNIT 53 Length unit on display
LCD_VOLUME_UNIT 54 Volume unit on display
LCD_TEMPERATURE_UNIT 55 Temperature unit on display
LCD_VELOCITY_UNIT 56 Velocity unit on display
MAX_INTERNAL_TEMPERATURE 57 The maximum temperature that has been measured inside
the device during operation
MIN_INTERNAL_TEMPERATURE 58 The minimum temperature that has been measured inside the
device during operation
OPERATION TIME 59 The total number of hours the device has been in operation
ENV_ENVIRONMENT 60 Process Condition
ENV_PRESENTATION 61 Tank Presentation
ENV_DEVICE_MODE 62 Service mode
ENV_WRITE_PROTECT 63 Write protect
DIAGN_DEVICE_ALERT 64 Errors, Warnings, Status, Plant web alerts
DIAGN_VERSION 65 Gauge SW version
DIAGN_REVISION 66 P1451 revision
DIAGN_DEVICE_ID 67 Device ID for the gauge.
DIAGN_DEVICE_MODEL 68 Type of 5300. LF or HF
STATS_ATTEMPTS 69 The total number of messages sent to the transducer A/D
board
STATS_FAILURES 70 The total number of failed A/D board message attempts
Parameter Index Number Description