AMPLITUDE_THRESHOLD_CURVE 13 ATC: filters out weak disturbance echoes and noise.
SIMULATION_MODE 14 Simulation of measurement values.
SET_CONSTANT_THRESHOLD 15 A constant amplitude threshold can be used to filter out noise.
RADAR_LEVEL_RANGE 16
RADAR_LEVEL_SIGNAL_STRENGT
H_RANGE
17
RADAR_VOLUME_RANGE 18
ENV_PRESENTATION 19
PROBE_END_THRESH 20 This threshold is used to locate the probe end echo. The probe
end echo is used by the device to know when the tank is empty,
but is sometimes also useful when no surface echo can be found.
REFERENCE_THRESH 21 This threshold is used to locate the reference echo.
INTERFACE_THRESH 22 This threshold is used to block out disturbing echoes and noise
when locating the interface echo.
FULL_TANK_THRESH_OFFSET 23 By adding an offset to the Reference Threshold it is possible for
the device to determine when the tank is full. If the reference echo
amplitude is between the Reference Threshold and the Full Tank
Threshold then the tank is considered full.
PEP_PRODUCT_DC 24 Enter the product dielectric constant for the product in the tank.
AUTO_CONF_MEAS_FUNC 25
ECHO_TIME_OUT 26 Change this parameter to define the time in seconds before the
device should start to search for a surface echo after it has been
lost.
CLOSE_DIST 27 This parameter defines a window centered at the current surface
position where new surface echo candidates can be selected. The
size of the window is +/-Close Distance. Echoes outside this
window will not be considered as surface echoes.
USED_PROBE_END_THRESH 28 Probe End Threshold currently used in the device.
USED_REFERENCE_THRESH 29 Reference Threshold currently used in the device.
USED_INTERFACE_THRESH 30 Interface Threshold currently used in the device.
USED_TANK_PRESENTATION 31
USED_ECHO_TIME_OUT 32 Echo Timeout currently used in the device.
USED_CLOSE_DIST 33 Close Distance currently used in the device.
SW_SUPPORT2 34 Defines what options are enabled in the device.
USED_HOLD_OFF_DIST 35 The upper null zone distance currently used in the device.
USED_PEP_PRODUCT_DC 36 Product Dielectric currently used in the device.
START_CODE 37 This code determines what options are available in your device.
Do not change your Start Code unless you have received a valid
one. Use Enter Start Codes method to change it.
UNIT_CODE 38 Unit code 1 -4 can be sent to your local Emerson representative in
order to receive new Start Codes for upgrading your device.
ENV_SET_START_CODE 39 Set Start Code
PROBE_END_ANCHORING 40
PEP_PROBE_END_OFFSET 41
USED_PEP_ PROBE_END_OFFSET 42
VOL_VOLUME_CALC_METHOD 43 Choose what kind of volume calculation method to use.
VOL_IDEAL_DIAMETER 44 Diameter of the tank (only for ideal tank shapes).
VOL_IDEAL_LENGTH 45 Length/height of the tank (only for ideal tank shapes).