Emerson Process Management 5300 Marine RADAR User Manual


 
Reference Manual
00809-0100-4530, Rev BA
July 2009
Rosemount 5300 Series
A-28
Code Hazardous Locations Certifications
NA No Hazardous Locations Certifications
E1 ATEX Flameproof
E3 NEPSI Flameproof
E5 FM Explosion-proof
E6 CSA Explosion-proof
E7 IECEx Flameproof
I1 ATEX Intrinsic Safety
IA ATEX FISCO Intrinsic Safety
(8)
I3 NEPSI Intrinsic Safety
IC NEPSI FISCO Intrinsic Safety
(8)
I5 FM Intrinsic Safety and Non-Incendive
IE FM FISCO Intrinsic Safety
(8)
I6 CSA Intrinsic Safety
IF CSA FISCO Intrinsic Safety
(8)
I7 IECEx Intrinsic Safety
IG IECEx FISCO Intrinsic Safety
(8)
KA ATEX, FM, CSA Flameproof/Explosion-proof
KB ATEX, FM, IECEx Flameproof/Explosion-proof
KC ATEX, CSA, IECEx Flameproof/Explosion-proof
KD FM, CSA, IECEx Flameproof/Explosion-proof
KE ATEX, FM, CSA Intrinsic Safety
KF ATEX, FM, IECEx Intrinsic Safety
KG ATEX, CSA, IECEx Intrinsic Safety
KH FM, CSA, IECEx Intrinsic Safety
KI FISCO - ATEX, FM, CSA Intrinsic Safety
(8)
KJ FISCO - ATEX, FM, IECEX Intrinsic Safety
(8)
KK FISCO - ATEX, CSA, IECEX Intrinsic Safety
(8)
KL FISCO - FM, CSA, IECEX Intrinsic Safety
(8)
Code Options
M1 Integral digital display
P1 Hydrostatic testing
(9)
LS Long stud 9.8 in (250 mm) for flexible single lead probe to prevent contact with wall/nozzle.
Standard height is 3.9 in (100 mm) for probes 5A and 5B; 5.9 in. (150 mm) for probes 6A and 6B.
T1 Transient Protection Terminal Block (standard with FISCO options)
BR Mounting Bracket for 1.5 in. NPT Process Connection (RA)
(10)
U1 WHG Overfill Approval (pending, consult the factory)
Special Configuration (Software)
C1 Factory configuration (CDS required with order)
C4 Namur alarm and saturation levels, high alarm
C5 Namur alarm and saturation levels, low alarm
C8 Low alarm
(11)
(standard Rosemount alarm and saturation levels)
Special Certifications
Q4 Calibration Data Certification
Q8 Material Traceability Certification per EN 10204 3.1
(12)
QG GOST Primary Verification Certificate
QS Prior-use certificate of FMEDA Data. Only available with HART 4-20 mA output (output code H).