Emerson Process Management 5300 Marine RADAR User Manual


 
Reference Manual
00809-0100-4530, Rev BA
July 2009
Rosemount 5300 Series
I-8
Table I-1.
RB.RECOMMENDED_ACTION
Alarm Type
Failed/Maint/Advise
Active Event
Recommended Action
Text String
PlantWeb Alerts
None None No action required
Advisory
Non-Volatile Writes Deferred Non-volatile writes have been deferred, leave
the device powered until the advisory goes
away.
Electronics Warning -
Transducer Block
Check device installation and configuration
PlantWeb Alerts Simulation Use the switch on the Fieldbus electronics
board to turn simulation on or off.
Maintenance
Probe Contamination Clean the probe.
Configuration Error Load default database to the device and
reconfigure it.
Configuration Warning Check device configuration
Simulation Mode Use Start / Stop Device Simulation to enable
or disable simulation.
Vapor Compensation
Warning
1. Recalibrate vapor compensation.
2. Check Vapor DC configuration.
3. Check that the correct probe is attached.
Volume/Temperature
Measurement Warning
1. Check volume configuration.
2. Check ambient temperature at installation
site.
3. If the surrounding temperature is OK, it
might indicate a hardware error producing
heat. Replace the transmitter head.
Failed
Level / Interface
Measurement Failure
1. Analyze echo curve for reason and check
device configuration.
2. Check device physical installation
(for instance probe contamination).
3. Load default database to the device and
reconfigure it.
4. If error persists, it might indicate a hardware
error. Replace the transmitter head.
Volume / Temperature
Measurement Failure
1. If Level Measurement Failure is active, clear
that alert first.
2. Check volume configuration.
3. Load default database to the device and
reconfigure it.
4. Check ambient temperature at installation site.
5. If error persists, it might indicate a hardware
error. Replace the transmitter head.
Electronics Failure -
Transducer Block
Replace transmitter head.
Probe Missing Check that the probe is properly connected.
Input / Output Failure Replace the transmitter.
Non-Volatile Memory Failure
1. Load default database to the device to clear
the error.
2. Download a device configuration.
3. If error persists, it may indicate a faulty
memory chip. Replace the transmitter head.
Electronics Failure - Output
Board
Replace the transmitter.
Software Incompatible Error Replace the device.