Emerson Process Management 5300 Marine RADAR User Manual


 
Reference Manual
00809-0100-4530, Rev BA
July 2009
A-25
Rosemount 5300 Series
PlantWeb Diagnostic Functionality
D01 FOUNDATION fieldbus Diagnostics Suite
DA1 HART Diagnostics Suite
Centering Discs Outer Diameter
S2 2 in. Centering disc
(24)
1.8 in. (45 mm)
S3 3 in. Centering disc
(24)
2.7 in. (68 mm)
S4 4 in. Centering disc
(24)
3.6 in. (92 mm)
S6 6 in. Centering disc
(24)
5.55 in. (141 mm)
S8 8 in. Centering disc
(24)
7.40 in. (188 mm)
P2 2 in. Centering disc PTFE
(25)
1.8 in. (45 mm)
P3 3 in. Centering disc PTFE
(25)
2.7 in. (68 mm)
P4 4 in. Centering disc PTFE
(25)
3.6 in. (92 mm)
P6 6 in. Centering disc PTFE
(25)
5.55 in. (141 mm)
P8 8 in. Centering disc PTFE
(25)
7.40 in. (188 mm)
Remote Housing Mounting
B1 1 m / 3.2 ft. Remote Housing Mounting Cable and Bracket
B2 2 m / 6.5 ft. Remote Housing Mounting Cable and Bracket
B3 3 m / 9.8 ft. Remote Housing Mounting Cable and Bracket
Consolidate to Chamber
XC Consolidate to Chamber
(26)
(1) Not available with Flame/Explosion-proof approvals (E1, E3, E5, E6, E7, KA, KB, KC, and KD)
(2) Process seal rating. Final rating depends on flange and O-ring selection.
(3) Requires option None for sealing (no O-ring).
(4) Welding Procedure Qualification Record Documentation will be supplied.
(5) For other materials, consult the factory.
(6) Consult the factory for this option.
(7) Requires High Temperature High Pressure (code H), High Pressure (code P), or Cryogenic (code C) probe.
(8) Requires model 5301.
(9) Only available with standard temperature and pressure (code S).
(10) Available in SST. Consult the factory for other materials.
(11) This is an HTHP probe.
(12) Extra length for fastening is added in factory.
(13) Probe weight included if applicable. Give the total probe length in feet and inches or meters and centimeters, depending on selected probe length unit.
If tank height is unknown, please round up to an even length when ordering. Probes can be cut to exact length in field. Maximum allowable length is
determined by process conditions.
(14) Available in 316L SST. For other materials consult the factory.
(15) Available in 316L SST (EN 1.4404). For other materials, consult the factory.
(16) Probes are intrinsically safe.
(17) Requires Foundation fieldbus signal output (U
i
parameter listed in Appendix B: Product Certifications).
(18) For standard tank connection, only available with flange .
(19) For Material SST, Alloy C-276 and Alloy 400; Probe Type 3A, 3B, 4A, 4B, 4U, and 4V.
(20) Not available with PTFE covered probes.
(21) Only for Material of Construction code 1 and 3. For other materials, consult the factory.
(22) The standard alarm setting is high.
(23) Certificate includes all pressure retaining wetted parts.
(24) Available for SST and Alloy C-276 probe, type 2A, 4A, 4B, and 5A. Same disc material as probe material.
(25) Available for probe types 2A, 4A, 4B, and 5A, except for HTHP.
(26) Not available for Cryogenic probe.
Example Model String: 5301-H-A-1-S-1-V-1A-M-002-05-AA-I1-M1C1. E-002-05, means 2 ft and 5 in. probe length. M-002-05, means 2.05 m