CYCLE_TYPE 19 Identifies the block execution methods available for this resource.
DD_RESOURCE 09 String identifying the tag of the resource which contains the Device Description for
this resource.
DD_REV 13 Revision of the DD associated with the resource - used by an interface device to locate
the DD file for the resource.
DEFINE_WRITE_LOCK 60 Allows the operator to select how WRITE_LOCK behaves. The initial value is “lock
everything”. If the value is set to “lock only physical device” then the resource and
transducer blocks of the device will be locked but changes to function blocks will be
allowed.
DETAILED_STATUS 55 Indicates the state of the transmitter. See Resource Block detailed status codes.
DEV_REV 12 Manufacturer revision number associated with the resource - used by an interface device
to locate the DD file for the resource.
DEV_STRING 43 This is used to load new licensing into the device. The value can be written but will
always read back with a value of 0.
DEV_TYPE 11 Manufacturer’s model number associated with the resource - used by interface devices
to locate the DD file for the resource.
DIAG_OPTION 46 Indicates which diagnostics licensing options are enabled.
DISTRIBUTOR 42 Reserved for use as distributor ID. No Foundation enumerations defined at this time.
DOWNLOAD_MODE 67 Gives access to the boot block code for over-the-wire downloads.
0 = Uninitialized
1 = Run mode
2 = Download mode
FAULT_STATE 28 Condition set by loss of communication to an output block, fault promoted to an output
block or physical contact. When FAIL_SAFE condition is set, then output function blocks
will perform their FAIL_SAFE actions.
FAILED_ACTIVE 72 Enumerated list of failure conditions within a device.
FAILED_ALM 73 Alarm indicating a failure within a device which makes the device non-operational.
FAILED_ENABLE 70 Enabled FAILED_ALM alarm conditions. Corresponds bit for bit to the FAILED_ACTIVE.
A bit on means that the corresponding alarm condition is enabled and will be detected. A
bit off means the corresponding alarm condition is disabled and will not be detected.
FAILED_MASK 71 Mask of FAILED_ALM. Corresponds bit of bit to FAILED_ACTIVE. A bit on means that
the condition is masked out from alarming.
FAILED_PRI 69 Designates the alarming priority of the FAILED_ALM.
FB_OPTION 45 Indicates which function block licensing options are enabled.
FEATURES 17 Used to show supported resource block options.
The supported features are: SOFT_WRITE_LOCK_SUPPORT,
HARD_WRITE_LOCK_SUPPORT, REPORTS, and UNICODE
FEATURES_SEL 18 Used to select resource block options.
FINAL_ASSY_NUM 54 The same final assembly number placed on the neck label.
FREE_SPACE 24 Percent of memory available for further configuration. Zero in a preconfigured device.
FREE_TIME 25 Percent of the block processing time that is free to process additional blocks.
GRANT_DENY 14 Options for controlling access of host computers and local control panels to operating,
tuning, and alarm parameters of the block. Not used by device.
HARD_TYPES 15 The types of hardware available as channel numbers.
HARDWARE_REV 52 Hardware revision of the hardware that has the resource block in it.
HEALTH_INDEX 84 Parameter representing the overall health of the device, 100 being perfect and 1 being
non-functioning. The value is based on the active PWA alarms.
ITK_VER 41 Major revision number of the inter operability test case used in certifying this device as
interoperable. The format and range are controlled by the Fieldbus Foundation.
LIM_NOTIFY 32 Maximum number of unconfirmed alert notify messages allowed.
MAINT_ACTIVE 77 Enumerated list of maintenance conditions within a device.
Parameter
Index
Number
Description