Omron 3G3FV-PDRT1-SIN Marine Radio User Manual


 
5-44
Constant Control mode settingChang
es dur-
ing op-
eration
Default
setting
Setting
range
Setting
unit
Regis-
ter No.
NameConstant
Flux
vector
Open
loop
vector
V/f with
PG
V/f
control
Chang
es dur-
ing op-
eration
Default
setting
Setting
range
Setting
unit
Regis-
ter No.
Name
E1-03 V/f pattern selection 0302 Hex 0 to F F No Yes Yes No No
E1-04 Maximum frequency
(FMAX)
0303 0.1 40.0 to 400.0 60.0 No Yes Yes Yes Yes
E1-05 Maximum voltage
(VMAX)
0304 0.1 0.0 to 255.0
(See note 1.)
200.0
(See
note 1.)
No Yes Yes Yes Yes
E1-06 Maximum voltage
frequency (FA)
0305 0.1 0.0 to 400.0 60.0 No Yes Yes Yes Yes
E1-07 Intermediate
frequency (FB)
0306 0.1 0.0 to 400.0 3.0
(See
note 2.)
No Yes Yes Yes No
E1-08 Intermediate voltage
(VC)
0307 0.1 0.0 to 255.0
(See note 1.)
11.0
(see
note 1,
2)
No Yes Yes Yes No
E1-09 Minimum frequency
(FMIN)
0308 0.1 0.0 to 400.0 0.5
(See
note 2.)
No Yes Yes Yes Yes
E1-10 Minimum voltage
(VMIN)
0309 0.1 0.0 to 255.0
(See note 1.)
2.0 (see
note 1,
2)
No Yes Yes Yes No
E1-11 Mid. Output
Frequency B
030A 0.1 0.0 to 400.0 0.0 No Yes Yes Yes Yes
E1-12 Mid. Output
Frequency Voltage B
030B 0.1 0.0 to 255.0
(See note 1.)
0.0 No Yes Yes Yes Yes
E1-13 Base Voltage 030C 0.1 0.0 to 255.0
(See note 1.)
0.0 No Yes Yes Yes Yes
E2-01 Motor rated current 030E 0.01
(See
note 5.)
0.32 to 6.40
(See note 4.)
1.90
(See
note 3.)
No Yes Yes Yes Yes
E2-02 Motor rated slip 030F 0.01 0.00 to 20.00 2.90
(See
note 3.)
No Yes Yes Yes Yes
E2-03 Motor no-load current 0310 0.01
(See
note 5.)
0.00 to 6.39
(See note 4.)
1.20
(See
note 3.)
No Yes Yes Yes Yes
E2-04 Number of motor
poles
0311 1 2 to 48 4 No No Yes No Yes
E2-05 Motor phase-to-phase
resistance
0312 0.001 0.000 to
65.000
9.842
(See
note 3.)
No Yes Yes Yes Yes
E2-06 Motor leakage
inductance
0313 0.1 0.0 to 30.0 18.2
(See
note 3.)
No No No Yes Yes
E2-07 Motor iron-core
saturation coefficient
1
0314 0.01 0.00 to 0.50 0.50 No No No Yes Yes
E2-08 Motor iron-core
saturation coefficient
2
0315 0.01 0.00 to 0.75 0.75 No No No Yes Yes
E2-09 Mechanical loss 0316 0.1 0.0 to 10.0 0.0 No No No No Yes
E3-01 Select control method
of motor 2
0317 1 0, 2 2 No Yes Yes Yes Yes
E4-01 Motor 2 maximum
frequency
0318 0.1 40.0 to 400.0 60.0 No Yes No Yes No
E4-02 Motor 2 maximum
voltage
0319 0.1 0.0 to 255.0
(See note 1.)
200.0
(See
note 1.)
No Yes No Yes No
CompoBus/D Communications Card Operations Chapter 5