Omron 3G3FV-PDRT1-SIN Marine Radio User Manual


 
7-17
H Ladder Program
00000
DIFU (013)
03000
MOV (021)
#0010
DM0100
MOV (021)
#0001
001
MOV (021)
#0000
DM0101
MOV (021)
#0003
DM0100
MOV (021)
#0021
DM0101
00100
03100
25506 (Equals Flag)
00002
00004
00004
03000
03000
ANDW (034)
DM1000
#FF00
DM0101
ORW (035)
DM0101
#0001
DM0101
ANDW (034)
DM1000
#00FF
DM0102
MOV (021)
#0010
DM0100
ANDW (034)
010
#00FF
DM0102
00100
00101
00102
MOV (021)
#0003
DM0100
MOV (021)
#0010
DM0101
00103
00002
00101
00102
00103
03002
CMP (020)
#0010
m
00100
XFER (070)
#0002
DM0100
n
ANDW (034)
m+1
#00FF
DM1002
CMP (020)
#0001
DM1002
03101
03100
ASL (025)
001
03101
00300
03002
MOVD (083)
DM0102
#0010
n+2
25506 (Equals Flag)
Sets frequency reference.
Sets control input.
Reads output frequency.
Reads Inverter status.
Communications Programs (SYSMAC C200HX/HG/HE PCs) Chapter 7