Omron 3G3FV-PDRT1-SIN Marine Radio User Manual


 
5-45
Constant Control mode settingChang
es dur-
ing op-
eration
Default
setting
Setting
range
Setting
unit
Regis-
ter No.
NameConstant
Flux
vector
Open
loop
vector
V/f with
PG
V/f
control
Chang
es dur-
ing op-
eration
Default
setting
Setting
range
Setting
unit
Regis-
ter No.
Name
E4-03 Motor 2 maximum
voltage frequency
031A 0.1 0.0 to 400.0 60.0 No Yes No Yes No
E4-04 Motor 2 intermediate
frequency
031B 0.1 0.0 to 400.0 3.0
(See
note 2.)
No Yes No Yes No
E4-05 Motor 2 intermediate
voltage
031C 0.1 0.0 to 255.0
(See note 1.)
11.0
(see
note 1,
2)
No Yes No Yes No
E4-06 Motor 2 minimum
frequency
031D 0.1 0.0 to 400.0 0.5
(See
note 2.)
No Yes No Yes No
E4-07 Motor 2 minimum
voltage
031E 0.1 0.0 to 255.0
(See note 1.)
2.0 (see
note 1,
2)
No Yes No Yes No
E5-01 Motor 2 rated current 031F 0.01
(See
note 5.)
0.32 to 6.40
(See note 4.)
1.90
(See
note 3.)
No Yes No Yes No
E5-02 Motor 2 rated slip 0320 0.01 0.00 to 20.00 2.90
(See
note 3.)
No Yes No Yes No
E5-03 Motor 2 no-load
current
0321 0.01
(See
note 5.)
0.00 to 6.39
(See note 4.)
1.20
(See
note 3.)
No Yes No Yes No
E5-04 Motor 2 number of
motor poles
0322 1 2 to 48 4 No No No No No
E5-05 Motor 2
phase-to-phase
resistance
0323 0.001 0.000 to
65.000
9.842
(See
note 3.)
No Yes No Yes No
E5-06 Motor 2 leakage
inductance
0324 0.1 0.0 to 30.0 18.2
(See
note 3.)
No No No Yes No
Note 1. These are values for a 200-V-class Inverter. Values for the 400-V-class Inverter are double
those given.
Note 2. When the control mode is changed, the Inverter will revert to default settings. (The open loop
vector control default settings will be displayed.)
Note 3. The default setting depends upon the type of Inverter. The value for a 200-V-class 0.4 kW
Inverter will be displayed.
Note 4. The setting range is 10% to 200% of the Inverters rated output current. The values for a
200-V-class 0.4 kW Inverter will be displayed.
Note 5. Units of 0.01 A are used for a capacity of 7.5 kW or below and units of 0.1 A are used for a
capacity of 11 kW or over.
Note 6. Motor 2 parameters depend on the E301 (motor 2 control mode selection) settings.
CompoBus/D Communications Card Operations Chapter 5