Omron 3G3FV-PDRT1-SIN Marine Radio User Manual


 
7-4
H Ladder Program
Forward/Stop Bit
(word n bit 0)
Reverse/Stop Bit
(word n bit 1)
Fault Flag
(03000)
Fault Reset Input Bit
(word n bit 2)
Reverse Operation
00001
03000
(word m bit 3)
Forward Operation
00002
03000
(word m bit 2)
00003
Fault Bit
(word m bit 0)
03000
00003
03003
03004
Net control
(word n bit 5)
During forward run
03001
(word m bit 2)
03003
03004
03004
During reverse run
(word m bit 3)
03002
Net reference
(word n bit 6)
See note
DIFU (013)
03001
00004
DIFD (014)
03002
Speed reference setting
00000
MOV (021)
DM0000
n+1
Note This program is not required if the b1-01 (Frequency Reference Selection) and b1-02 (Inverter
Run Command Selection) are set to 3.
Communications Programs (SYSMAC C200HX/HG/HE PCs) Chapter 7