Omron 3G3FV-PDRT1-SIN Marine Radio User Manual


 
8-9
Instance SizeWriteReadDefault
(Hex)
Setting
range
ContentNameAttribute
02
Remote
I/O
01 State Indicates the status of this
object (instance).
00: Does not exist in
network, or is not ready.
01: In network state, waiting
for connection event from
Master Unit.
02: Waiting for connection
ID (attribute) writing.
03: Connection completed.
04: Timeout
--- Must be
03
when
commu-
nications
are es-
tab-
lished.
Yes No Byte
02 Instance type Indicates the type of object
(instance).
00: Explicit message
01: Remote I/O
--- 01 Yes No Byte
03 Transport class trigger Indicates the
communications
configuration for the
CompoBus/D
Communications Card.
--- 82 Yes No Byte
04 Produced connection ID
Indicates the label used for
the communications header
for the CompoBus/D
--- --- Yes No Word
05 Consumed connection
ID
Communications Card.
Note: These are set when
the communications
connection is made.
--- --- Yes No Word
06 Initial comm
characteristics
Indicates the
communications
configuration for the
CompoBus/D
Communications Card.
--- 01 Yes No Byte
Appendices Chapter 8