Lucent Technologies 6.1 Marine Radio User Manual


 
MERLIN LEGENDCommunications System Release 6.1
System Planning
555-661-112
Issue 1
August 1998
T1/PRI Planner
Page D-4
D
The communications system in Figure D–1 is configured as follows:
Module 1 in slot 04 is connected to an ACCULINK 3150 CSU that is
approximately 100 cable feet from the control unit. (The DS1 facility is
connected to the PRI network.)
Module 2 in slot 05 is connected to an ACCULINK 3150 CSU that is
approximately 160 cable feet from the control unit. (The far end is another
communications system.)
The primary clock synchronization source is the PRI network connected to
Module 1. Its path is shown by a line and the letter
P.
The secondary clock synchronization path, shown by a line and the letter
S, is the system internal clock.
Figure D–1. Sample DS1 Planning Map
CONTROL UNIT
100D
MODULE 1
SLOT:____
100D
MODULE 2
SLOT:____
100D
MODULE 3
SLOT:____
Approximate
Distance_____
Approximate
Distance_____
Approximate
Distance_____
CSU
Acculink 3150
Other*
None
Acculink 3150
Other*
None
Acculink 3150
Other*
None
Connection 1
CO
PBX
PRI**
* Other model numbers
** The switching equipment
of the service provider
must be 4ESS Generic 13 or later
or 5ESS G6 or later.
Key:
Digital Transmission
Facility
Primary Synchronization
Source
Secondary Synchronization
Source
Tertiary Synchronization
Source
P
S
T
Clock
CSU CSU
DS1 Planning Map
Tie
LS
GS
DID
S56 Data
Services
T1 Emulated Trunks
Connection 2
CO
PBX
PRI**
Tie
LS
GS
DID
S56 Data
Services
T1 Emulated Trunks
Connection 3
CO
PBX
PRI**
Tie
LS
GS
DID
S56 Data
Services
T1 Emulated Trunks
04
100 ft 160 ft
05
S
P