Unit Load Calculation
Page F-6Unit Load Worksheet
F
7. Try to exchange modules between carriers to reduce the unit loads to 75 (if a
391C1 or 391A3 power supply is installed) or 54 (if a 391A1 or 391A2 power
supply is installed). (Remember that the 100D, 800 NI-BRI, 400 LS, 400 GS/LS,
800, and 800 GS/LS modules have unit loads of 0.0.) Repeat Steps 1 through 6
to recalculate unit loads for the new configuration.
NOTES:
Empty slots are not permitted between modules.
If the exchange reduces the unit load to below the rated maximum for your
power supply module, no further calculation is required.
If your system has a 391A1 or 391A2 power supply and the exchange does
not reduce the unit load to 54, replace the 391A1 or 391A2 power supply
with a 391C1 power supply. If your system has a 391C1 or 391A3 power
supply and the exchange does not reduce the unit load to 75, continue to
Step 8.
8. Calculate the unit load for slots 5 and 6 of the carrier using the table on the
next page.
If the unit load for slots 5 and 6 is less than or equal to 27, power is
sufficient for the carrier.
If the unit load for slots 5 and 6 is more than 27, continue to Step 9.