Lucent Technologies 6.1 Marine Radio User Manual


 
MERLIN LEGENDCommunications System Release 6.1
System Planning
555-661-112
Issue 1
August 1998
Unit Load Calculation
Page F-7Unit Load Worksheet
F
* Unit loads are computed for each trunk for trunk-type network access lines.
The MFM has its own wall power unit located at the telephone and, therefore, is not added to
the unit load calculation.
Up to two DSSs (one DSS for each MLX-28D or MLX-20L) can be powered from each control
unit carrier. For example, a three-carrier system can have six system operator positions, each
with one DSS powered from the control unit.
Module Qty x Unit Load = Total
Equipment
Hybrid/PBX
or Modified
Key
Network Access Lines*
DID 1.0 0.0
DS1 0.0 0.0
NI-1 BRI 0.0 0.0
GS/LS 0.0 0.0
Tie 1.4 1.4
Telephones
MLX-10 0.9 1.2
MLX-10D 0.9 1.2
MLX-10DP 0.9 1.2
MLX-28D 1.2 1.7
MLX-20L 1.1 1.6
BIS-10 0.9 1.1
BIS-22 1.0 1.3
BIS-22D 1.0 1.3
BIS-34 1.1 1.5
BIS-34D 1.1 1.5
MLC-5 0.0 0.0
MDC 9000
0.0 0.0
MDW 9000
0.0 0.0
10-Button Basic
0.9 1.1
10-Button HFAI
1.0 1.2
34-Button Basic
0.9 1.1
34-Button DLX
1.2 1.7
34-Button BIS
1.2 1.4
34-Button BIS/DIS
1.2 1.4
Single-Line Telephone
0.6 0.7
Optional Equipment
Direct Station Selector
0.7 0.9
General-Purpose Adapter
0.8 1.0
Hands-Free Unit
0.8 1.0
Headset Adapter
0.8 1.0
Total Actual Unit Load