Graco 3A2098H Life Jacket User Manual


 
Appendix C - Communications Gateway Module (CGM) Connection Details
136 3A2098H
* Maintenance dispensed volume/time can only be set
to 0.
Swirl Commands
0x29E Pressure Units Pressure Units Enu-
meration
Read /
Write
0x29F Rate Units Rate Units Enumera-
tion
Read /
Write
0x2A0 Maintenance
Volume Units
Volume Units Enumer-
ation
Read /
Write
0x2A1 Maintenance
Mass Units
Mass Units Enumera-
tion
Read /
Write
0x2A2 Maintenance
Time Units
Mass Units Enumera-
tion
Read /
Write
0x2AD Valve 1 Swirl
Association
(Swirl Zone)
Swirl Enumeration Read /
Write
0x2AE Valve 2 Swirl
Association
(Swirl Zone)
Swirl Enumeration Read /
Write
0x2AF Valve 3 Swirl
Association
(Swirl Zone)
Swirl Enumeration Read /
Write
0x2B0 Valve 4 Swirl
Association
(Swirl Zone)
Swirl Enumeration Read /
Write
0x2B5 End Job On
Alarm
Boolean Read /
Write
0x3FB Style Bits ### Read /
Write
0x115 Command
Value
uint12 Read /
Write
0x116 Error Reset /
Remote Start
Dispense Control 2 Bit-
field
Read /
Write
0x118 Disable Dis-
pensing
Boolean Read /
Write
0x3FF Dispense Con-
trol
Dispense Control 1 Bit-
field
Read /
Write
0x0FB Inlet Pressure Pressure: #### (psi);
###.# (bar); ##.##
(Mpa)
Read Only
0x0FC Outlet Pres-
sure
Pressure: #### (psi);
###.# (bar); ##.##
(Mpa)
Read Only
0x0DC Pressure Com-
mand
Pressure: #### (psi);
###.# (bar); ##.##
(Mpa)
Read Only
0x403 Flowrate Com-
mand
##### cc/min Read Only
0x404 Flowrate
Actual
##### cc/min Read Only
0x406 Fluid Plate Sta-
tus 0
Fluid Plate Status 0
bitfield
Read Only
0x409 Fluid Plate
Faults
Gateway Error Number Read Only
Output
Bits
256-267 Description
Units
*See Units
Definitions, page 137
Read or
Write
0x0FF Fluid Plate Dis-
pensed Vol-
ume
#####.# (cc) Read Only
0x0DB Active Fault
Error Code
Fault Error Code Read Only
0x0F8 Fluid Plate Sta-
tus Bits
Fluid Plate Status bit-
field
Read Only
0x0FE Requested Vol-
ume
#####.# (cc) Read Only
Output
Bits
264-275 Description Gateway Units
Read or
Write
0x004 Software Part
Number
STR_3_0 Read Only
0x005 Software Part
Number
STR_7_4 Read Only
0x006 Software Part
Number
STR_11_8 Read Only
0x007 Software Part
Number
STR_15_12 Read Only
0x00B Software Version Version Read Only
0x400 Swirl Speed
Source
Speed Source
Enumeration
Read /
Write
0x401 Swirl Fixed Speed ##### (RPM) Read /
Write
0x403 Swirl Speed Scal-
ing
### (percent) Read /
Write
0x404 Swirl Maintenance
Time Advisory
Limit
###### (hours) Read /
Write
0x3FF Swirl - Actual Run
Time
###### (hours) Read /
Write
0x2FC Swirl Status Bits 1 Swirl Status Bit-
field 1
Read Only
0x4FE Swirl Actual Speed ##### (RPM) Read Only
0x500 Swirl Control Swirl Control
Enumeration
Read /
Write
0x501 Swirl Requested
Speed
uint12 Read /
Write
Output
Bits
256-267 Description
Units
*See Units
Definitions, page 137
Read or
Write