Models
4 3A2098H
Models
Check the identification (ID) plate for the 6-digit part number of the fluid metering system. Use the following matrix to
define the construction of the system, based on the six digits. For example, Part PF1110 represents a PCF fluid
metering system (PF), a two style system (1), a fluid plate with a cartridge regulator and no meter (1), a DeviceNet
™
user interface (1) with a 100-240 Vac power supply (0).
NOTE: To order replacement parts, see Parts section in this manual. The digits in the matrix do not correspond to the
Ref. Nos. in the Parts drawings and lists.
◆
Discrete Gateway systems do not include automation interface cables. The following Graco accessories are avail-
able for wiring to the automation system. Installers should follow Appendix B - Discrete Gateway Module
(DGM) Connection Details, page 115, for custom wiring.
For single fluid plate systems only: 50 ft (15 m) cable with flying leads (123793)
All systems: Breakout board (123783) and 50 ft (15 m) cable (123792)
NOTE: 256 styles option is not available with Discrete Gateway systems.
❄
These fluid metering systems have ETL certification.
NOTE: Fluid metering systems with heated mastic regulators are not ETL certified.
This product has been tested to the requirements of CAN/CSA-C22.2 No. 61010-1, second edition, including
Amendment 1, or a later version of the same standard incorporating the same level of testing requirements.
PF 1
1
1
0
First and
Second Digits
Third Digit
Fourth Digit
Fifth Digit
Sixth Digit
Style/Size
Fluid Plate
User Interface
Voltage
Description Regulator Meter Description Description
PF
(Precision
Continuous
Flow)
1 2 Styles 1 ❄Cartridge None 0 ◆Discrete 0 100 - 240 Vac
2
16 Styles 2 ❄Mastic None 1
DeviceNet
™
1 24 Vdc
3 256 Styles 3 ❄Cartridge High
Resolution
2
EtherNet/IP
™
2 100 - 240 Vac with
Integrated Swirl
4 ❄Mastic High
Resolution
3
PROFIBUS
™
3 24 Vdc with
Integrated Swirl
5 Heated
Mastic
Heated
Standard
Resolution
4
PROFINET
™
6 Heated
Mastic
None
7 ❄Cartridge Ultra High
Resolution
9902471
Certified to CAN/CSA C22.2 No. 61010-1
Conforms to
UL 61010-1
C
1