Mount Four-Valve Breakout Kit 24B693
PCF is capable of controlling up to four separate dis-
pense valves from port 1 on the FCM. A four-valve
breakout kit (24B693) is available to split the dispense
solenoid connector (port 1 on the FCM) into four sepa-
rate dispense solenoid connectors. For each additional
dispense valve, order one dispense valve
solenoid (258334) and one solenoid cable (121806).
Follow this procedure if using the four-valve breakout
kit.
1. Remove the existing dispense solenoid and cable
from the fluid plate.
2. Install bulkhead fitting (included in the kit) into the
empty hole on the fluid plate.
3. Connect one end of the extension cables (included
in the kit) to connection 1 on the FCM and the other
end of the cable to the bulkhead fitting.
4. Connect the splitter assembly to the bulkhead fit-
ting.
5. Connect the dispense valve cable(s) to the connec-
tions on the splitter assembly.
6. Mount splitter assembly and dispense valves, and
connect air lines as necessary for application.
Custom Breakout Cable
If desired, the following connector pinout information
may be used to build a custom breakout cable:
Pinout of FCM Port 1
Pin 1: Dispense Solenoid 4
Pin 2: Dispense Solenoid 2
Pin 3: Voltage - (common for all solenoids)
Pin 4: Dispense Solenoid 1
Pin 5: Dispense Solenoid 3
Dispense solenoid outputs are 24 Vdc. Dispense sole-
noid outputs are capable of sourcing up to 0.5A each
(maximum 12W coil).
F
IG
. 16: Mount Breakout Kit
GCA Cable
Splitter Assembly
Hole for bulk-
head fitting
Connection 1
J1 J3
J2 J4
Cable for:
Connects to Splitter
Connection Labeled:
Dispense Valve 1 J1
Dispense Valve 2 J2
Dispense Valve 3 J3
Dispense Valve 4 J4