Maintenance
76 3A2098H
Maintenance
Prior to performing any maintenance procedures, follow
the Pressure Relief Procedure on page 57.
Maintenance Schedule
The following tables list the recommended maintenance procedures and frequencies to operate the equipment
safely. The maintenance is divided between mechanical and electrical tasks. Maintenance must be performed by
trained personnel per this schedule to assure safety and reliability of the equipment.
Mechanical
Electrical
* Check Component Manual for more detailed maintenance information.
Operator Maintenance Person
Task Daily Weekly Monthly
3-6
months
or
125,000
cycles
18-24
months
or
500,000
cycles
36-48
months
or
1,000,000
cycles
7000
hours
Inspect system for leaks
✓
Depressurize fluid, after opera-
tion
✓
Remove heat from system,
after operation
✓
Inspect filter (234967) bowls
and drain
✓
Check hoses for wear
✓
Check/tighten fluid connections ✓
Check/tighten air connections ✓
Lubricate dispense valves*
✓
Rebuild regulator*
✓
Rebuild dispense valve*
✓
Replace air filter
✓
Replace Solenoid
✓
Replace Voltage to Pressure
(V/P) Transducer
✓
* Check component manual for more detailed maintenance information.
Task Weekly
Check cables for wear
✓
Verify cable connections
✓
Verify operation of “System Stop” button
✓