Graco 3A2098H Life Jacket User Manual


 
Errors
68 3A2098H
Fluid Plate Events and Errors
EBUX --- Download to
USB Complete
Download to the USB is
complete
Advisory
(self-clearing)
--- No action necessary
WSU0 --- USB configura-
tion error
USB configuration error Advisory USB configuration
invalid or not present
Reinstall system soft-
ware on display
WNC0 32 ADM Key Token
Error
Missing or invalid key
token
Alarm An ADM key token is
required to run the
system
Verify the key token is
installed
Verify the key token
part number is correct
for the PCF ADM
WNG0 --- Gateway Map
Error
Missing or invalid map Advisory Missing or invalid
Gateway map
Install PCF map in
Gateway
CBG0 --- Gateway Reset Gateway reset Advisory
(self-clearing)
Gateway setting(s)
changed
Wait for reset to com-
plete before attempt-
ing automation control
WMG0 --- Gateway Error
Detected
Gateway error
detected; includes any
error not covered by
another more specific
error
Alarm --- ---
CBD_ --- Fluid Plate Com-
munication Error
Fluid Plate Communi-
cation Error with ADM
Alarm The ADM lost commu-
nications with the
FCM.
Restore communica-
tion.
CCG_ --- Fieldbus Com-
munication Error
Fieldbus Communica-
tion Error
Alarm The automation gate-
way lost communica-
tion with the
automation controller.
Restore communica-
tions.
Event
Code
Gateway
Error No. Event Name
Event
Description Event Type Cause Solution
Control Center Events and Errors
Event
Code
Gateway
Error No. Event Name
Event
Description Event Type Cause Solution
Fluid Plate Events and Errors
CAC_ --- CGM Communi-
cation Error
Communication lost
between CGM and
Fluid Plate
Advisory Fluid Plate and CGM
are no longer commu-
nicating
Reconnect or replace
CAN cable
CGM is not functioning Replace the CGM if the
red status LED is solid
CAD_ --- Fluid Plate Com-
munication Error
FCM lost communica-
tion with the ADM
Alarm ADM is not communi-
cating
Reconnect or replace
CAN cable
ADM is not functioning Replace FCM if red
status LED is solid
ADM does not contain
appropriate key token
Verify intended ADM
key token is properly
inserted
B7C_ 30 Style Out of
Range
Style is out of range Alarm Style requested by
automation controller
exceeds number of
styles available on the
fluid plate
Use a style number
that is in range
Increase number of
styles in PCF; pur-
chase accessory key
token