Graco 3A2098H Life Jacket User Manual


 
USB Data
3A2098H 59
USB Data
All files downloaded from the USB are put in a DOWN-
LOAD folder on the drive. For example:
“E:\GRACO\12345678\DOWNLOAD\”
The 8-digit numeric folder name matches the 8-digit
ADM serial number. When downloading from multiple
ADMs, there will be one sub-folder in the GRACO folder
for each ADM.
USB Logs
During operation, PCF stores system and performance
related information to memory in the form of log files.
PCF maintains three types of log files: a job log, an
event log, and dispense data logs. Follow the Down-
load Procedure, page 61, to retrieve log files.
Event Log
The event log file name is 1-EVENT.CSV and is stored
in the DOWNLOAD folder.
The event log maintains a record of the last 1,000
events. Each event record in the log file contains the
date and time the event occurred, the event type, event
code, and event description.
Job Log
The job log file name is 2-JOB.CSV and is stored in the
DOWNLOAD folder.
The job log maintains a record of the last 10,000 jobs. At
the completion of each job the following data is stored in
the log file:
Job completion date
Job completion time
Job number (sequential number)
Dispenser (Fluid Plate) Number
Style number
Target volume (in the units shown in the volume
units column)
Requested volume (in the units shown in the
volume units column)
Actual dispensed volume (in the units shown in
the volume units column)
Volume units
Error percentage between actual dispensed vol-
ume and requested volume (maximum of
100%)
Minimum inlet pressure during job (measured in
bar, heated systems will always read 0)
Average inlet pressure during job (measured in
bar, heated systems will always read 0)
Maximum inlet pressure during job (measured
in bar, heated systems will always read 0)
Minimum outlet pressure during job (measured
in bar)
Average outlet pressure during job (measured
in bar)
Maximum outlet pressure during job (measured
in bar)
Minimum flow rate during job (measured in
cc/min, systems with no flow meter will read 0)
Average flow rate during job (measured in
cc/min, systems with no flow meter will read 0)
Maximum flow rate during job (measured in
cc/min, systems with no flow meter will read 0)
Elapsed time (mS)
Dispense Data Log
The dispense data log file name is 3-DATAx.CSV and is
stored in the DOWNLOAD folder. There is one dispense
data log file for each installed fluid plate, so there can be
up to four data logs.
The dispense data log maintains a record of system inlet
pressure (heated systems will always read 0), system
outlet pressure, system flow rate (systems without flow
meters will always read 0), and active dispense valves.
This data is recorded at one second intervals when a job
cycle is in process. Each dispense data log is capable of
storing up to two hours of data.
F
IG
. 39: ADM USB Port