69 Low Pressure Measured outlet pres-
sure less than desired
outlet pressure minus
tolerance
Alarm or
Deviation
(user select-
able)
Incorrect limit set Verify limit is set cor-
rectly
No or insufficient
material flow
Increase material flow
rate
Dispense valve nee-
dle is stuck closed
Dislodge and inspect
needle
Dispense valve leak-
ing
Repair dispense valve
Regulator not operat-
ing correctly
Repair regulator
Pump wink passed
through outlet
Increase pump pres-
sure
Failed transducer Check transducer;
replace if failed
P3C_
P4C_
70 High Pressure Measured outlet pres-
sure greater than
desired outlet pressure
plus tolerance
Alarm or
Deviation
(user select-
able)
Incorrect limit set Verify limit is set cor-
rectly
Dispense hose/device
plugged
Clean/replace
hose/device
Failed transducer Check transducer;
replace if failed
Regulator is not clos-
ing completely when it
should
Repair regulator
F1D_
F2D_
71 Low Flow Rate Measured flow rate less
than desired flow rate
minus tolerance
Alarm or
Deviation
(user select-
able)
Fluid supply too low to
achieve desired flow
rate
Increase fluid supply
pressure or check for
clogged filter
Tip plugged Clean/replace tip
No air pressure to
solenoid valves
Turn on air to solenoid
valves
No flow meter signal Check cable and sen-
sor
No material supply Replace drum or turn
on pumps
Incorrect flow toler-
ance of flow error time
Enter correct toler-
ance or flow error time
F3D_
F4D_
72 High Flow Rate Measured flow rate
greater than desired
flow rate plus tolerance
Alarm or
Deviation
(user select-
able)
Operating below mini-
mum regulator operat-
ing pressure
Increase fluid pres-
sure above regulator
minimum
Regulator worn or not
operating correctly
Repair regulator
Flow meter providing
false pulses
Replace flow meter
sensor
Incorrect flow error tol-
erance or flow error
time
Enter correct toler-
ance or flow error time
EKD_ 73 Shot Terminated
by Job Timer
Shot dispense cycle
terminated by job timer
Advisory Job end timer was
used to stop shot dis-
pense
No action required if
timed shot is desired
EHD_ 74 Purge Timer
Expired
Purge timer expired Advisory PCF purge timer (style
0) has expired
Automation control
requests purge
Event
Code
Gateway
Error No. Event Name
Event
Description Event Type Cause Solution
Fluid Plate Events and Errors