Graco 3A2098H Life Jacket User Manual


 
Errors
70 3A2098H
WED_ 55 V/P Error Voltage to Pressure
Transducer error
Alarm Problem detected with
V/P
Verify outlet pressure
transducer is installed
and/or connected cor-
rectly
Replace if necessary
WJ1_ 56 Dispense Valve 1
Error
Dispense valve 1 error Alarm Problem detected with
dispense valve 1
Verify dispense valve 1
is installed and/or con-
nected correctly
Replace if necessary
WJ2_ 57 Dispense Valve 2
Error
Dispense valve 2 error Alarm Problem detected with
dispense valve 2
Verify dispense valve 2
is installed and/or con-
nected correctly
Replace if necessary
WJ3_ 58 Dispense Valve 3
Error
Dispense valve 3 error Alarm Problem detected with
dispense valve 3
Verify dispense valve 3
is installed and/or con-
nected correctly
Replace if necessary
WJ4_ 59 Dispense Valve 4
Error
Dispense valve 4 error Alarm Problem detected with
dispense valve 4
Verify dispense valve 4
is installed and/or con-
nected correctly
Replace if necessary
WSD_ 60 Incompatible
Valve Settings
Incompatible settings
for multiple valve opera-
tion; attempted to dis-
pense
Alarm Attempted to dis-
pense simultaneously
from multiple valves
on the same fluid plate
with different pressure
settings
Check settings shown
on Fluid Plate x,
screen 2 (Mode Set-
tings)
Verify automation pro-
gramming
WSD5 60 Incompatible
Valve Settings
Incompatible settings
for multiple valve opera-
tion; attempted to dis-
pense
Alarm Attempted to dis-
pense simultaneously
from multiple valves
on the same fluid plate
with different pressure
settings
In the Discrete Gate-
way screens, change
the settings of the
simultaneously dis-
pensing valves to the
same pressure
Verify automation pro-
gramming
F7D_ 61 Closed Valve
Flow
System reading flow
meter pulses with
valve(s) closed
Alarm Dispense hose leak Check hose; replace if
needed
Flow meter providing
false pulses
Replace flow meter
sensor or calibrate
meter
Dispense valve not
operating correctly
Repair dispense valve
Event
Code
Gateway
Error No. Event Name
Event
Description Event Type Cause Solution
Fluid Plate Events and Errors