V2D_ 62 Low Analog Command cable analog
command dropped
below minimum value
of 1 V while dispensing
Deviation Bad or loose com-
mand cable connec-
tion
Check command cable
and connection
Entered command
mode incorrectly
Enter correct com-
mand code
Automation program
error
Verify correct automa-
tion program
WFD_
WFG_
63 Flow Meter
Required
Operating mode
requires flow meter.
Advisory is issued if
fluid plate settings
require a flow meter but
meter is not present.
Alarm is issued if dis-
pense is attempted in
mode that requires a
flow meter but meter is
not present.
Alarm or
Advisory
(self-clearing)
Selected valve mode
settings require flow
meter
Check valve mode set-
tings
Purchase meter
enabled token for FCM
and install flow meter
FCM key token miss-
ing or invalid
Check for FCM key
token error
EJD_ 64 Job Cycle Time
Out
Job cycle time out Alarm Automation signals did
not properly end job
cycle
Check automation pro-
gramming per job oper-
ating instruction
WXD_ 65 Fluid Plate Error
Detected
Fluid plate error
detected; includes any
error not covered by
another more specific
error
Alarm Analog voltage applied
to pin 1 of the com-
mand cable exceeds
10 Vdc.
Limit signal on pin 1 of
command cable to the
range of 0-10 Vdc.
Failed FCM Replace FCM if neces-
sary
P3F_
P4F_
66 Maximum Inlet
Pressure
Inlet pressure to regula-
tor is above upper limit
set for operation
Alarm or
Deviation
(user select-
able)
Incorrect set limit Verify limit is set cor-
rectly
Material supply pres-
sure is too high
Decrease material
supply pressure
Failed transducer Check transducer;
replace if necessary
P3D_
P4D_
67 Maximum Outlet
Pressure
Outlet pressure of regu-
lator is above upper
limit set for operation
Alarm or
Deviation
(user select-
able)
Incorrect set limit Verify limit is set cor-
rectly
Material supply pres-
sure is too high
Decrease material
supply pressure
Failed transducer Check transducer;
replace if necessary
P1F_
P2F_
68 Minimum Inlet
Pressure
Inlet pressure to regula-
tor is below lower limit
set for operation
Alarm or
Deviation
(user select-
able)
Incorrect set limit Verify limit is set cor-
rectly
Material supply pres-
sure is too low
Increase crease mate-
rial supply pressure
Failed transducer Check transducer;
replace if necessary
Event
Code
Gateway
Error No. Event Name
Event
Description Event Type Cause Solution
Fluid Plate Events and Errors