Mitsubishi Electronics MDS-B Life Jacket User Manual


 
Chapter 10 Adjustment
10–31
3) When power supply control axis is different driver than vertical axis servo axis (Example:
When vertical axis is Y axis, and axis connected to power supply is Z axis)
3)-1: When vertical axis and power supply axis are 1-axis driver
X axis
(B-V14/V24)
Y axis
(B-V14)
Z axis
(B-V14)
Spindle
(B-SP)
Axis
Parameter
settin
g
Vertical axis
Axis connected to
power supply
Separate power supply
connection (only spindle)
SV48 0
Set with
adjustments
Set same value as
Y axis
SV55 0
Set same value
as SV48
Set same value as
Y axis
SV56 0
Set same value
as rapid traverse
time constant
Set same value as
rapid traverse time
constant
Does not relay on software.
When the vertical axis and power supply axis differ, the servo parameters must be set for both axes.
3)-2: When vertical axis and power supply axis are 2-axis driver
X axis
(B-V14/V24)
Y axis
(B-V24)
Z axis
(B-V24)
A axis
(B-V14)
Spindle
(B-SP)
Axis
Parameter
setting
Vertical axis
2-axis servo driver
Axis connected
to power supply
Separate power
supply connection
(only spindle)
SV48 0
Set with
adjustments
Set same value
as Y axis
Set same value
as Y axis
SV55 0
Set same value
as SV48
Set same value
as Y axis
Set same value
as Y axis
SV56 0
Set same value
as rapid traverse
time constant
Set same value
as rapid traverse
time constant
Set same value
as rapid traverse
time constant
Does not relay on
software.
When vertical axis is 2-axis driver, set for both L and M axes.
CNC
X
Y
Z
Spindle
Power supply
Power supply
B-CV
B-
V14/V24
B-
V14
B-
V14
B-SP
B-CV
CNC
XY,A
Z
Spindle Power supply
Power supply
B-CV
B-
V14/V24
B-
V14
B-
V24
B-SP
B-CV