Chapter 7 Installation
7–11
7-2-6 Connection of feedback cable
Peel the sheath of the feedback cable where indicated below to expose the shield cover. Ground this
section with a cable clamp, etc. Normally, only the cable to which the scale is connected is grounded
on the servo amplifier side or I/F unit side. However, if the distance between the servo amplifier and
scale I/F unit is 5m or more, also ground this cable.
CNC
MDS-B-V14L
MDS-B-V14L
MDS-B-MD
Scale I/F unit
Incremental linear scale
Absolute position linear scale (AT342 special)
Absolute position linear scale
CON2
CON3
CON4
CN1A
CN1BCN4
CN2
CN3
CN1A
CN1BCN4
CN2
CN3
<Required>
Peel the clamp sheath at a
point near the servo
amplifier, and ground with a
cable clamp.
<Required>
Peel the cable sheath at a point near
the I/F unit, and ground with a cable
clamp.
<Required depending on
conditions>
If the distance between the servo
amplifier and scale I/F unit is 5m
or more, peel the cable sheath at
a point near the servo amplifier,
and ground with a cable clamp.
This also applies when
connecting the scale I/F unit to
CON1.
CON1