Chapter 8 Drive Section Connector and Cable Specifications
8–15
8-5-3 Cable for amplifier – scale I/F unit
<CNL2H2-S cable connection diagram>
This is an actual connection diagram for the CNL2H2-S cable supplied by Mitsubishi. The
connection differs according to the cable length.
(15 to 30m)
6
16
7
17
19
10
20
1
11
PE
SD
SD*
RQ
RQ*
P5(+5V)
P5(+5V)
LG
LG
Case
grounding
Am
p
lifier side CN2
,
3
Scale I/F unit side CON1, 2
3
4
1
2
5
6
7
8
FG
10120-3000VE
RM15WTP-8S
(15m or less)
6
16
7
17
19
10
20
1
11
PE
SD
SD*
RQ
RQ*
P5(+5V)
P5(+5V)
LG
LG
Case
grounding
Amplifier side CN2, 3
Scale I/F unit side CON1, 2
3
4
1
2
5
6
7
8
FG
10120-3000VE