Chapter 7 Installation
7–4
(2) Installation of secondary side
1) Direction
When using multiple secondary sides, lay the units out so that the nameplates on the
products all face the same direction in order to maintain the pole arrangement.
Nameplate
2) Procedures
Install with the following procedure to eliminate clearances between the secondary sides.
Secondary side used as
installation reference.
1. Press against.
2. Fix with bolt.
CAUTION
1. Use nonmagnetic tools when installing the secondary side.
2. When placing the secondary side onto the installation surface, use the
screws on the product, and suspend with eye bolts, etc.
3. If the secondary side is already installed and another secondary side is
being added, place the secondary side away from the side already installed,
and then slide the additional secondary side to the specific position.
7-1-3 Cooling of linear servomotor
(1) A cooling pipe is embedded on the primary side of the linear motor, so flow at least 5 liters of
cooling oil per minute.
(2) When using with natural cooling, the continuous rating will be 50% compared to when using
cooling oil.