IV
5. Various precautions
Observe the following precautions. Incorrect handling of the unit could lead to faults, injuries and
electric shocks, etc.
(1) Transportation and installation
CAUTION
Correctly transport the product according to its weight.
Do not stack the products above the tolerable number.
Do not hold the front cover when transporting the servo amplifier. The unit could drop.
Follow this Instruction Manual and install the unit in a place where the weight can be borne.
Always store the secondary side of the linear servomotor in the delivered packaged state.
Do not get on top of or place heavy objects on the unit.
Always observe the installation directions.
During the interval from unpacking to installation, the risks posed by the magnetic attraction
force in the secondary side of the linear servomotor will increase, so take special care, and
install the correctly.
Secure the specified distance between the servo amplifier and control panel, or between the
servo amplifier and other devices.
Do not install or run a servo amplifier or linear servomotor that is damaged or missing parts.
Do not let conductive objects such as screws or metal chips, etc., or combustible materials such
as oil enter the servo amplifier or linear servomotor.
The servo amplifier and linear servomotor are precision devices, so do not drop them or apply
strong impacts to them.
Store and use the units under the following environment conditions.
Conditions
Environment
Servo
amplifier
Scale I/F
unit
Pole
detec-tion
unit
Linear servomotor
Ambient temperature
0°C to +55°C
(with no dew condensation)
0°C to +40°C
(with no dew condensation)
Ambient humidity
90% (RH) or less
(with no dew condensation)
80% (RH) or less
(with no dew condensation)
Storage temperature
–15°C to +70°C
(with no freezing)
–15°C to +50°C
(with no freezing)
Storage humidity
90% (RH) or less (with no dew condensation)
Atmosphere
Indoors (Where unit is not subject to direct sunlight)
With no corrosive gas, combustible gas, oil mist or dust.
Altitude 1000m or less above sea level
Vibration
4.9m/s
2
98m/s
2
98m/s
2