Chapter 8 Drive Section Connector and Cable Specifications
8–12
8-4 Cable wire and assembly
The following shows the specifications and processing of the wire used in each cable. Use the
following recommended wires or equivalent part when manufacturing the cable, and make sure not to
mistake the connection.
Core size
[mm
2
] × pair
Core insulation
sheath type
(Note) d [mm]
Recommended wire type
0.08 × 10
UL20276
AWG28 10pair (BLACK)
0.2 × 8
UL20276
AWG24 8pair (BLACK)
0.3 × 8
0.9 to 1.27
UL20276
AWG22 7pair (BLACK)
(Note) d is as shown below.
d
Securely connect the cable shield wire to the connector's ground plate as shown below.
Ground plate
SheathShield (external conductor)
Core wire
Sheath
Shield (external conductor)
Core wire
Conductor
Installation sheath
Core cross-section