Mitsubishi Electronics FR-E700 Marine Battery User Manual


 
117
PARAMETERS
5
Setting of acceleration/deceleration time and acceleration/ deceleration pattern
(2) Deceleration time setting (Pr. 8, Pr. 20)
Use Pr. 8 Deceleration time to set the deceleration time required to reach 0Hz from Pr. 20 Acceleration/deceleration reference
frequency.
Set the deceleration time according to the following expression.
(3) Change the setting range and increments of the acceleration/deceleration time (Pr. 21)
Use Pr. 21 to set the acceleration/deceleration time and minimum setting range.
Value "0" (initial value) ...........................0 to 3600s (minimum setting increments: 0.1s)
Value "1" .................................................0 to 360s (minimum setting increments: 0.01s)
(1) Acceleration time setting (Pr. 7, Pr. 20)
Use Pr. 7 Acceleration time to set the acceleration time required to reach Pr. 20
Acceleration/deceleration reference frequency from 0Hz.
Set the acceleration time according to the following formula.
Acceleration
time setting
=
Pr. 20
×
Acceleration time from a stop to the
maximum operating frequency
Maximum operating
frequency - Pr. 13
Example) How to find the setting value for Pr.7 when increasing the output
frequency to the maximum frequency of 50Hz in 10s with Pr.20 = "60Hz
(initial setting)" and Pr. 13 = "0.5Hz (initial setting)."
Pr. 7 =
60Hz
×
10s 12.1s
50Hz - 0.5Hz
Deceleration
time setting
=
Pr. 20
× Deceleration time from the maximum operating frequency to a stop
Maximum operating frequency - Pr. 10
Example) How to find the setting value for Pr.8 when decreasing the output
frequency from the maximum frequency of 50Hz in 10s with Pr.20 =
"120Hz" and Pr. 10 = "3Hz (initial setting)."
Pr. 8 =
120Hz
×
10s 25.5s
50Hz-3Hz
NOTE
Changing the Pr. 21 setting changes the acceleration/deceleration time setting (Pr. 7, Pr. 8, Pr. 16, Pr. 44, Pr. 45).
(It does not influence the setting of Pr. 611 Acceleration time at a restart .)
<Example>
When Pr. 7 is set to "5.0s" at Pr. 21 setting of "0", and then Pr. 21 is changed to "1", the Pr. 7 setting automatically
changes to "0.5s".
Running
frequency
Acceleration time
Pr. 7, Pr. 44
Deceleration time
Pr. 8, Pr. 45
Time
Pr. 20
(60Hz)
(Hz)
Output
frequency