Mitsubishi Electronics FR-E700 Marine Battery User Manual


 
64
Message transmission
(4) Inverter status
Monitors the output signal of the inverter from network.
When accessing a message, the access size should be the size stated in the table above.
<Word block read (inverter status)>
(5) Set frequency
Set frequency can be read from RAM or EEPROM in 0.01Hz increments.
When accessing a message, the access size should be the size stated in the table above.
<Word block read (set frequency (EEPROM/RAM))>
<Word block read (set frequency (RAM))>
(6) Inverter monitor
Inverter monitored value can be read.
<Word block read (inverter monitor)>
Virtual address
(byte boundary)
Applications
Message
Access
Address
(word boundary)
Size
(word boundary)
Description Read Write
H100000DC 110 1 Inverter status ×
Item Data Portion
Request Not applicable
Response
Normal
response
Inverter status is returned. (Refer to page 59 for details)
Error
response
Virtual address
(byte boundary)
Applications
Message
Access
Address
(word boundary)
Size
(word boundary)
Description Read Write
H100000F0 120 1 Set frequency (EEPROM/RAM) ×
H100000F2 121 1 Set frequency (RAM) ×
Item Data Portion
Request Not applicable
Response
Normal
response
Set frequency is returned.
H0000 to HFFFF (0.01Hz increments)
Error
response
REMARKS
y Regardless of the Pr.37 setting, the value is always displayed in frequency (Hz).
Item Data Portion
Request Not applicable
Response
Normal
response
Inverter monitor value is returned.
Error
response
Offset Bit15 to Bit0
+0 Inverter status
Offset Bit15 to Bit0
+0 Error code (Refer to page 61)
Offset Bit15 to Bit0
+0 Set frequency
Offset Bit15 to Bit0
+0 Error code (Refer to page 61)
Offset Bit15 to Bit0
+0 Inverter monitor value (Refer to page 65)
Offset Bit15 to Bit0
+0 Error code (Refer to page 61)