5.22 Initial value change list
Displays and sets the parameters changed from the initial value.
Operation Display
1. Screen at power-ON
The inverter starts up in the Network operation
mode. The monitor display appears.
2. Change the X12 signal (Bit11) setting to "1."
X12 signal (Bit11) gives a control input
command through FL remote communication.
3. Press to choose the PU operation mode.
PU indicator is lit.
4. Press to choose the parameter setting
mode.
PRM indicator is lit.
(The parameter number read previously appears.)
5. Turn until appears.
6. Pressing changes to the initial value
change list screen.
It may take several seconds for
creating the initial value change
list.
" " flickers while
creating the list.
7. Turning displays the parameter number
changed.
Press to read the currently set value.
Turn and press to change the
setting
(refer to step 6 and 7 on page 76)
Flicker Parameter setting complete!!
Turn to read another parameter.
The display returns to after all
parameters are displayed.
8. Pressing in status returns to
the parameter setting mode.
Turning sets other parameters.
Pressing displays the change list again.
NOTE
Only simple mode parameter is displayed when simple mode is set (Pr. 160 = 9999)
Only user group is displayed when user group is set (Pr. 160 = "1").
Pr. 160 is displayed independently of whether the setting value is changed or not.
When parameter setting is changed after creating the initial value change list, the setting will be reflected to the initial
value change list next time.
Parameters referred to
Pr. 160 User group read selection Refer to page 167