Operation mode setting
4.5 Operation mode setting
4.5.1 Operation mode basics
The operation mode specifies the source of the start command and the frequency command for the inverter.
Basically, there are following operation modes.
Network operation mode (NET operation mode): For inputting a start command and a frequency command through FL
remote communication.
PU operation mode: For inputting start command and frequency command with the operation panel.
At power-on, the inverter starts up in the Network operation mode. The operation mode can be switched using on the
operation panel when "1" is set in the X12 signal (Bit11). X12 signal gives a control input command through FL remote
communication. (Refer to page 57)
Confirm the operation mode from the operation panel. (Refer to page 74)
REMARKS
y The stop function (PU stop selection) activated by pressing of the operation panel is valid even in other than the
PU operation mode in the initial setting.
(Refer to Pr. 75 Reset selection/PU stop selection (page 165))
Network
operation mode
PU operation mode
Personal computer
Operation panel
Programmable controller
Inverter
FL remote communication connector