Mitsubishi Electronics FR-E700 Marine Battery User Manual


 
129
PARAMETERS
5
Selection and protection of a motor
(2) Setting
1) Select Advanced magnetic flux vector control (Refer to page 95) or General-purpose magnetic flux vector control (Refer to
page 98).
2) Set "1" or "11" in Pr. 96 Auto tuning setting/status.
When the setting is "1" .......Tune all motor constants without running the motor.
When performing Advanced magnetic flux vector control, set "1" to perform tuning.
It takes approximately 25 to 75suntil tuning is completed.
(Excitation noise is produced during tuning.)
Tuning time differs according to the inverter capacity and motor type.
When the setting is "11"......Tune motor constants (R1) only without running the motor.
When performing General-purpose magnetic flux vector control, set "11" to perform
tuning.
It takes approximately 9s until tuning is completed.
3) Set the rated motor current (initial value is rated inverter current) in Pr. 9 Electronic thermal O/L relay. (Refer to page 123)
4) Set the rated voltage of motor (initial value is 200V/400V) in Pr. 83 Rated motor voltage and rated motor frequency (initial
value is 60Hz) in Pr. 84 Rated motor frequency.
(For a Japanese standard motor, etc. which has both 50Hz and 60Hz rated values, use it with an initial value (200V/60Hz
or 400V/60Hz).
5) Set Pr. 71 Applied motor according to the motor used.
Motor Pr. 71 Setting ∗1
Mitsubishi standard motor
Mitsubishi high efficiency motor
SF-JR 3
SF-JR 4P 1.5kW or less 23
SF-HR 43
Others 3
Mitsubishi constant-torque motor
SF-JRCA 4P 13
SF-HRCA 53
Others (SF-JRC, etc.) 13
Other manufacturer's
standard motor
—3
Other manufacturer's
constant-torque motor
—13
∗1 Refer to page 125, for other settings of Pr. 71.