Parameter listParameter list
86
5
PARAMETERS
Parameter List
Stop-on
contact
control
275
Stop-on contact excitation current low-
speed multiplying factor
0 to 300%, 9999 0.1% 9999 139 275 × {{{{
276
PWM carrier frequency at stop-on
contact
0 to 9, 9999 1 9999 139 276 × { { { {
277
Stall prevention operation current
switchover
0, 1 1 0 101 277 {{{{{
278
Parameter for manufacturer setting. Do not set.
278
Parameter for manufacturer setting. Do not set.
279 279
280 280
281 281
282 282
283 283
Droop
control
286 Droop gain 0 to 100% 0.1% 0% 173 286 × { × { {
287 Droop filter time constant 0 to 1s 0.01s 0.3s 173 287 × { × {{
292 Automatic acceleration/deceleration 0, 1, 7, 8, 11 1 0 121 292 { { { { {
293
Acceleration/deceleration separate
selection
0 to 2 1 0 121 293 {{{{{
295 Magnitude of frequency change setting 0, 0.01, 0.1, 1, 10 0.01 0 185 295 { { { { {
Password
function
296 Password lock level
0 to 6, 99, 100 to 106,
199, 9999
1 9999 169 296 {{{× {
297 Password lock/unlock
(0 to 5), 1000 to 9998,
9999
1 9999 169 297 { { { × {
298 Frequency search gain 0 to 32767, 9999 1 9999 151 298 {{{× {
299
Rotation direction detection selection
at restarting
0, 1, 9999 1 0 151 299 { { { { {
338
Parameter for manufacturer setting. Do not set.
338
Parameter for manufacturer setting. Do not set.
339 339
340 340
342 342
343 343
Second motor
constant
450 Second applied motor 0, 1, 9999 1 9999 125 450 { { { { {
495
Parameter for manufacturer setting. Do not set.
495
Parameter for manufacturer setting. Do not set.
496 496
497 497
500 500
501
Communication error occurrence count
display
010161 501 {{{{{
502 Parameter for manufacturer setting. Do not set. 502 Parameter for manufacturer setting. Do not set.
Maintenance
503 Maintenance timer 0 (1 to 9998) 1 0 180 503 {{{××
504
Maintenance timer alarm output set
time
0 to 9998, 9999 1 9999 180 504 { { { × {
547
Parameter for manufacturer setting. Do not set.
547
Parameter for manufacturer setting. Do not set.
548 548
549 549
550 550
551 551
555 555
556 556
557 557
563 Energization time carrying-over times (0 to 65535) 1 0 147 563 {{{××
564 Operating time carrying-over times (0 to 65535) 1 0 147 564 { { { × ×
571 Holding time at a start 0 to 10s, 9999 0.1s 9999 119 571 {{{{{
611 Acceleration time at a restart 0 to 3600s, 9999 0.1s 9999 151 611 { { { { {
Func-
tion
Parameter
Name Setting Range
Minimum
Setting
Increments
Initial
Value
Refer
to
Page
Customer
Setting
Parameter
Control Mode-based
Correspondence Table
Parameter
Clear
All clear
V/F
V/F
V/F
AD
MFVC
AD
MFVC
AD
MFVC
GP
MFVC
GP
MFVC
GP
MFVC