Mitsubishi Electronics FR-E700 Marine Battery User Manual


 
168
Misoperation prevention and parameter setting restriction
(3) Registration of parameter to user group (Pr. 173)
(4) Deletion of parameter from user group (Pr. 174)
When registering Pr. 3 to user group
Operation Display
1. Confirm the operation display and operation
mode display.
The inverter should be at a stop.
Make sure that the inverter is in PU
operation mode.
2. Press to choose the parameter setting
mode.
Parameter setting mode
3. Turn to change the set value to
"".
Displays Pr. 173 User group
registration
4. Press to display .
When Pr. 173 is read, "9999"
is displayed
5. Turn until Pr. 3 appears.
Select the parameter number
to be registered.
6. Press to set.
" " and " " are displayed alternately.
To continue parameter registration, repeat
steps 3 to 6.
Flicker...Registration of Pr. 3 to user group
completed!!
When deleting Pr. 3 from user group
Operation Display
1. Confirm the operation display and operation
mode display.
The inverter should be at a stop.
The inverter should be in the PU operation
mode.
2. Press to choose the parameter setting
mode.
Parameter setting mode
3. Turn until appears.
Displays Pr. 174 User group
clear
4. Press to display " "
When Pr. 174 is read, "9999" is
displayed
5. Turn until Pr. 3 appears.
Select the parameter number
to be registered.
6. Press to set.
" " and " " are displayed alternately.
To continue parameter clear, repeat steps 3 to 6.
Flicker...Clear of Pr. 3 to user group completed!!
REMARKS
Pr. 77 and Pr. 160 can always be read, independently of the user group setting.
Pr. 77, Pr. 160 and Pr. 172 to Pr. 174 cannot be registered to the user group.
When Pr. 174 is read, "9999" is always displayed. Although "9999" can be written, no function is available.
When any value other than "9999" is set to Pr. 172, no function is available.