Mitsubishi Electronics FR-E700 Marine Battery User Manual


 
183
PARAMETERS
5
Setting from the operation panel
5.20.2 Operation panel frequency setting/key lock operation selection (Pr. 161)
The above parameters can be set when Pr. 160 User group read selection = "0". (Refer to page 167)
(1) Using the setting dial like a potentiometer to set the frequency.
The setting dial of the operation panel can be used for setting like a potentiometer.
The key operation of the operation panel can be disabled.
Parameter
Number
Name Initial Value
Setting
Range
Description
161
Frequency setting/key lock
operation selection
0
0 Setting dial frequency setting
Key lock invalid
1 Setting dial potentiometer
10 Setting dial frequency setting
Key lock valid
11 Setting dial potentiometer
Operation example Changing the frequency from 0Hz to 60Hz during operation
Operation Display
1. Screen at power-ON
The inverter starts up in the Network operation
mode. The monitor display appears.
2. Change the X12 signal (Bit11) setting to "1."
X12 signal (Bit11) gives a control input
command through FL remote communication.
3. Press to choose the PU operation mode.
PU indicator is lit.
4. Press to choose the parameter setting
mode.
PRM indicator is lit.
(The parameter number read previously
appears.)
5. Turn until (Pr. 161) appears.
6. Press to read the currently set value.
" "(initial value) appears.
7. Turn to change it to the set value " ".
8. Press to set.
Flicker Parameter setting complete!!
9. Mode/monitor check
Press twice to choose the monitor/
frequency monitor.
10.Press to start the inverter.
11.Turn until " " appears.
The flickering frequency is the set frequency.
You need not press .
The frequency flickers for about 5s.