PARAMETERS
5
Selection and protection of a motor
5.9.2 Applied motor (Pr. 71, Pr. 450)
The above parameters can be set when Pr. 160 User group read selection = "0". (Refer to page 167)
(1) Set the motor to be used
Refer to the following list and set this parameter according to the motor used.
Setting of the used motor selects the thermal characteristic appropriate for the motor.
Setting is required to use a constant-torque motor. Thermal characteristic of the electronic thermal relay function
suitable for the motor is set.
When General-purpose magnetic flux vector or Advanced magnetic flux vector control is selected, the motor constants
(SF-JR, SF-HR, SF-JRCA, SF-HRCA, etc.) necessary for control are selected as well.
Parameter
Number
Name
Initial
Value
Setting Range Description
71 Applied motor
0
0, 1, 3 to 6, 13 to 16,
23, 24, 40, 43, 44,
50, 53, 54
Selecting the standard motor or constant-torque
motor sets the corresponding motor thermal
characteristic.
450 Second applied motor
9999
0, 1 Set when using the second motor.
9999
Second motor is invalid
(thermal characteristic of the first motor
(Pr. 71))
Pr. 71 (Pr. 450)
Setting
Thermal Characteristic of the Electronic Thermal Relay Function
Motor (: Used motor)
Pr. 71 Pr. 450
Standard
(SF-JR, etc.)
Constant-torque
(SF-JRCA, etc.)
0
(Pr. 71 initial value)
Thermal characteristics of a standard motor
1 Thermal characteristics of the Mitsubishi constant-torque motor
40 Thermal characteristic of Mitsubishi high efficiency motor (SF-HR) ∗1
50 Thermal characteristic of Mitsubishi constant-torque motor (SF-HRCA) ∗2
3 Standard motor
Select "Offline auto tuning setting"
13 Constant-torque motor
23
Mitsubishi standard motor
(SF-JR 4P 1.5kW or less)
43 Mitsubishi high efficiency motor (SF-HR) ∗1
53
Mitsubishi constant-torque motor (SF-
HRCA)
∗2
4 Standard motor
Auto tuning data can be read,
changed, and set.
14 Constant-torque motor
24
Mitsubishi standard motor
(SF-JR 4P 1.5kW or less)
44 Mitsubishi high efficiency motor (SF-HR) ∗1
54
Mitsubishi constant-torque motor (SF-
HRCA)
∗2
5 Standard motor
Star
connection
Direct input of
motor constants is
enabled
15 Constant-torque motor
6 Standard motor
Delta
connection
16 Constant-torque motor
9999
(initial
value)
Without second applied motor
∗1 Motor constants of Mitsubishi high efficiency motor SF-HR.
∗2 Motor constants of Mitsubishi constant-torque motor SF-HRCA.
REMARKS
When performing offline auto tuning, set any of "3, 13, 23, 43, 53" in Pr. 71.
(Refer to page 127 for offline auto tuning.)
For the 5.5K and 7.5K, the Pr. 0 Torque boost and Pr. 12 DC injection brake operation voltage settings are automatically changed
according to the Pr. 71 setting as follows.
NOTE
Set the electronic thermal relay function to the thermal characteristic for the constant-torque motor when using a
geared motor (GM-S, GM-D, GM-SY, GM-HY2 series) to perform Advanced magnetic flux vector control or General-
purpose magnetic-flux vector control.
Automatic Change
Parameter
Standard Motor
Setting ∗1
Constant-torque Motor
Setting ∗2
Pr. 0 3% 2%
Pr. 12 4% 2%
∗1 Pr. 71 setting: 0, 3 to 6, 23, 24,40, 43, 44
∗2 Pr. 71 setting: 1, 13 to 16, 50, 53, 54