FL REMOTE COMMUNICATION FUNCTION
Message transmission
Inverter monitor value of each monitor is as in the table below.
(When accessing a message, the access size should be 2 bytes (1 word).)
Output terminal monitor details
(7) Parameter
Inverter parameters can be read or written through the network.
Refer to the Chapter 5 for details of the parameters.
When accessing a message, the access size should be the size stated in the table above.
<Word block read (parameter)>
<Word block write (parameter)>
b15 b0
——————————
ALM
signal
FU
signal
———
Termin al
Y0
Virtual address
(byte boundary)
Applications
Message
Access
Address
(word boundary)
Size
(word boundary)
Description Read Write
H100007D0 1000 1 Pr. 0 
H100007D2 1001 1 Pr. 1 
H100007D4 1002 1 Pr. 2 
:
H10000F9C 1998 1 Pr. 998 
H10000F9E 1999 1 Pr. 999 
Item Data Portion
Request Not applicable
Response
Normal
response
Specified parameter values return.
Error
response
Item Data Portion
Request
Specified parameter values are written.
Response
Normal
response
Not applicable
Error
response
REMARKS
y Parameter write is available only when "1" is set in the X12 signal (Bit11), which gives a control input command
through FL remote communication. (Refer to page 57)
(Note that the Pr.77 setting cannot be written through FL remote communication.)
Code number Description Unit
H10000190 Output frequency 0.01Hz
H10000192 Output current 0.01A
H10000194 Output voltage 0.1V
H10000198 Set frequency 0.01Hz
H1000019C Motor torque 0.1%
H1000019E Converter output voltage 0.1V
H100001A0 Regenerative brake duty 0.1%
H100001A2
Electronic thermal relay function
load factor
0.1%
H100001A4 Output current peak value 0.01A
H100001A6 Converter output voltage peak value 0.1V
H100001AA Output power 0.01kW
H100001AE Output terminal status
H100001B6 Cumulative energization time 1h
H100001BC Actual operation time 1h
H100001BE Motor load factor 0.1%
H100001C0 Cumulative power 1kWh
H10000208 Motor thermal load factor 0.1%
H1000020A Inverter thermal load factor 0.1%
H1000020C Cumulative power 2 0.01kWh
Code number Description Unit
Offset Bit15 to Bit0
+0 Parameter value
Offset Bit15 to Bit0
+0 Error code (Refer to page 61)
Offset Bit15 to Bit0
+0 Parameter value
Offset Bit15 to Bit0
+0 Error code (Refer to page 61)