Parameter listParameter list
80
5
PARAMETERS
Parameter List
30 Regenerative function selection 0, 1, 2 1 0
136,
151
30 {{{{{
Frequency jump
31 Frequency jump 1A 0 to 400Hz, 9999 0.01Hz 9999 106 31 { { { { {
32 Frequency jump 1B 0 to 400Hz, 9999 0.01Hz 9999 106 32 {{{{{
33 Frequency jump 2A 0 to 400Hz, 9999 0.01Hz 9999 106 33 { { { { {
34 Frequency jump 2B 0 to 400Hz, 9999 0.01Hz 9999 106 34 {{{{{
35 Frequency jump 3A 0 to 400Hz, 9999 0.01Hz 9999 106 35 { { { { {
36 Frequency jump 3B 0 to 400Hz, 9999 0.01Hz 9999 106 36 {{{{{
37 Speed display 0, 0.01 to 9998 0.001 0 146 37 { { { { {
40 RUN key rotation direction selection 0, 1 1 0 182 40 {{{{{
Frequency
detection
41 Up-to-frequency sensitivity 0 to 100% 0.1% 10% 144 41 { { { { {
42 Output frequency detection 0 to 400Hz 0.01Hz 6Hz 144 42 {{{{{
43
Output frequency detection for reverse
rotation
0 to 400Hz, 9999 0.01Hz 9999 144 43 { { { { {
Second functions
44 Second acceleration/deceleration time 0 to 3600/360s 0.1/0.01s 5/10/15s ∗2 116 44 {{{{{
45 Second deceleration time 0 to 3600/360s, 9999 0.1/0.01s 9999 116 45 { { { { {
46 Second torque boost 0 to 30%, 9999 0.1% 9999 94 46 { ××{{
47 Second V/F (base frequency) 0 to 400Hz, 9999 0.01Hz 9999 107 47 { × × { {
48
Second stall prevention operation
current
0 to 200%, 9999 0.1% 9999 101 48 {{{{{
51 Second electronic thermal O/L relay 0 to 500A, 9999 0.01A 9999 123 51 { { { { {
52 DU/PU main display data selection
0, 5, 7 to 12, 14, 20,
23 to 25, 52 to 57, 61,
62, 100
10147 52 {{{{{
54
Parameter for manufacturer setting. Do not set.
54
Parameter for manufacturer setting. Do not set.—55 55
56 56
Automatic restart
functions
57 Restart coasting time 0, 0.1 to 5s, 9999 0.1s 9999 151 57 {{{{{
58 Restart cushion time 0 to 60s 0.1s 1s 151 58 { { { { {
59 Remote function selection 0, 1, 2, 3 1 0 113 59 {{{{{
60 Energy saving control selection 0, 9 1 0 162 60 { × × { {
Automatic acceleration
/deceleration
61 Reference current 0 to 500A, 9999 0.01A 9999 121 61 {{{{{
62 Reference value at acceleration 0 to 200%, 9999 1% 9999 121 62 { { { { {
63 Reference value at deceleration 0 to 200%, 9999 1% 9999 121 63 {{{{{
65 Retry selection 0 to 5 1 0 158 65 { { { { {
—66
Stall prevention operation reduction
starting frequency
0 to 400Hz 0.01Hz 60Hz 101 66 {{{{{
Retry
67 Number of retries at fault occurrence 0 to 10, 101 to 110 1 0 158 67 { { { { {
68 Retry waiting time 0.1 to 360s 0.1s 1s 158 68 {{{{{
69 Retry count display erase 0 1 0 158 69 { { { { {
70 Special regenerative brake duty 0 to 30% 0.1% 0% 136 70 {{{{{
71 Applied motor
0, 1, 3 to 6, 13 to 16, 23,
24, 40, 43, 44, 50, 53, 54
1 0
95, 98,
125,
127,
71 { { { { {
72 PWM frequency selection 0 to 15 1 1 163 72 {{{{{
73
Parameter for manufacturer setting. Do not set.
73
Parameter for manufacturer setting. Do not set.
—74 74
75 Reset selection/PU stop selection 0 to 3, 14 to 17 1 14 165 75 { { { × ×
77∗6 Parameter write selection 0, 1, 2 1 0 166 77 {{{{{
78 Reverse rotation prevention selection 0, 1, 2 1 0 167 78 { { { { {
79 Parameter for manufacturer setting. Do not set. 79 Parameter for manufacturer setting. Do not set.
Func-
tion
Parameter
Name Setting Range
Minimum
Setting
Increments
Initial
Value
Refer
to
Page
Customer
Setting
Parameter
Control Mode-based
Correspondence Table
Parameter
Clear
All clear
V/F
V/F
V/F
AD
MFVC
AD
MFVC
AD
MFVC
GP
MFVC
GP
MFVC
GP
MFVC