FL REMOTE COMMUNICATION FUNCTION
Message transmission
<Word block read (manufacturer name)>
<Word block read (product name)>
<Word block read (inverter capacity)>
(3) Operation mode
Read the operation mode of the inverter from network.
When accessing a message, the access size should be the size stated in the table above.
<Word block read (operation mode)>
Item Data Portion
Request Not applicable
Response
Normal
response
Returns "MITSUBISHI ELECTRIC CORPORATION". The rest are the characters for space.
Error
response
Item Data Portion
Request Not applicable
Response
Normal
response
For the 200V class FR-E700, "FR-E720" is returned. The rest are the characters for space.
Error
response
Item Data Portion
Request Not applicable
Response
Normal
response
Inverter capacity is returned.
Error
response
Virtual address
(byte boundary)
Applications
Message
Access
Address
(word boundary)
Size
(word boundary)
Description Read Write
H100000C8 100 1 Operation mode ×
Item Data Portion
Request
Not applicable
Response
Normal
response
Operation mode is returned.
Error
response
Offset Bit15 to Bit8 Bit7 to Bit0
+0 Second character First character
+1 Fourth character Third character
:
+49 Hundredth character Ninety ninth character
Offset Bit15 to Bit0
+0 Error code (Refer to page 61)
Offset Bit15 to Bit8 Bit7 to Bit0
+0 Second character First character
+1 Fourth character Third character
:
+19 Fortieth character Thirty ninth character
Offset Bit15 to Bit0
+0 Error code (Refer to page 61)
Offset Bit15 to Bit0
+0 Inverter Capacity
Inverter Capacity Value
0.1kW 1
0.2kW 2
:
15kW 150
Offset Bit15 to Bit0
+0 Error code (Refer to page 61)
Offset Bit15 to Bit0
+0 Operation mode
Operation mode Value
PU operation H0001
PUJOG operation H0003
Network operation H0004
Offset Bit15 to Bit0
+0 Error code (Refer to page 61)