Mitsubishi Electronics FR-E700 Marine Battery User Manual


 
Parameter listParameter list
82
5
PARAMETERS
Parameter List
Motor constants
80 Motor capacity 0.1 to 15kW, 9999 0.01kW 9999
93, 95,
98,
127
80 × { { { {
81 Number of motor poles 2, 4, 6, 8, 10, 9999 1 9999
93, 95,
98,
127
81 × {{{{
82 Motor excitation current
0 to 500A (0 to ****), 9999
∗5
0.01A (1) ∗5 9999 127 82 × { { × {
83 Rated motor voltage 0 to 1000V 0.1V
200V/400V
∗4
127 83 × {{{{
84 Rated motor frequency 10 to 120Hz 0.01Hz 60Hz 127 84 × { { { {
89
Speed control gain (Advanced
magnetic flux vector)
0 to 200%, 9999 0.1% 9999 95 89 × { ××{
90 Motor constant (R1)
0 to 50Ω (0 to ****) ,
9999
∗5
0.001Ω (1) ∗5 9999 127 90 { { { × {
91 Motor constant (R2)
0 to 50Ω (0 to ****) ,
9999
∗5
0.001Ω (1) ∗5 9999 127 91 × {{× {
92 Motor constant (L1)
0 to 1000mH (0 to 50Ω,
0 to ****), 9999
∗5
0.1mH
(0.001Ω, 1)
∗5
9999 127 92 × { { × {
93 Motor constant (L2)
0 to 1000mH (0 to 50Ω,
0 to ****) , 9999
∗5
0.1mH
(0.001Ω, 1)
∗5
9999 127 93 × {{× {
94 Motor constant (X)
0 to 100% (0 to 500Ω, 0
to ****) , 9999
∗5
0.1%
(0.01Ω, 1)
∗5
9999 127 94 × { { × {
96 Auto tuning setting/status 0, 1, 11, 21 1 0
127,
151
96 {{{× {
117
Parameter for manufacturer setting. Do not set.
117
Parameter for manufacturer setting. Do not set.
—118 118
119 119
120 120
121 121
122 122
123 123
124 124
125 125
126 126
127 127
128 128
129 129
130 130
131 131
132 132
133 133
134 134
145 145
146 146
147
Acceleration/deceleration time
switching frequency
0 to 400Hz, 9999 0.01Hz 9999 116 147 { { { { {
Current
detection
150 Output current detection level 0 to 200% 0.1% 150% 145 150 {{{{{
151
Output current detection signal delay
time
0 to 10s 0.1s 0s 145 151 { { { { {
152 Zero current detection level 0 to 200% 0.1% 5% 145 152 {{{{{
153 Zero current detection time 0 to 1s 0.01s 0.5s 145 153 { { { { {
156 Stall prevention operation selection 0 to 31, 100, 101 1 0 101 156 {{{{{
157 OL signal output timer 0 to 25s, 9999 0.1s 0s 101 157 { { { { {
160 User group read selection 0, 1, 9999 1 0 167 160 {{{{{
161
Frequency setting/key lock operation
selection
0, 1, 10, 11 1 0 183 161 { { { × {
Func-
tion
Parameter
Name Setting Range
Minimum
Setting
Increments
Initial
Value
Refer
to
Page
Customer
Setting
Parameter
Control Mode-based
Correspondence Table
Parameter
Clear
All clear
V/F
V/F
V/F
AD
MFVC
AD
MFVC
AD
MFVC
GP
MFVC
GP
MFVC
GP
MFVC