Mitsubishi Electronics C6/C64 Life Jacket User Manual


 
APPENDIX 6 OUTLINE AND INSTALLATION DIMENSIONS FOR GROUNDING PLATE AND
CLAMP FITTING
I - 84
APPENDIX 6 OUTLINE AND INSTALLATION DIMENSIONS FOR
GROUNDING PLATE AND CLAMP FITTING
The shield wire generally only needs to be grounded
to the connector's case frame. However, the effect
can be improved by directly grounding to the
grounding plate as shown on the right.
Install the grounding plate near each unit. Peel off
part of the cable sheath as shown on the right to
expose the shield sheath. Press that section against
the grounding plate with the clamp fitting. Note that if
the cable is thin, several can be clamped together.
Install the grounding plate directly onto the cabinet or
connect a grounding wire so that sufficient frame
grounding is achieved.
If the AERSBAN-
SET, containing the grounding
plate and clamp fitting, is required, please contact
Mitsubishi.
Clamp section drawing
Clamp fitting
Fitting A,B
Grounding
Plate
Cable
Shield sheath
40
Outline drawing
Grounding plate
2-
φ
5 hole
Installation hole
17.5
M4 screw
Note 1)
6
22
35
10
MAX L
Clamp fitting
A
35
C
24
-0.2
0
B±0.3
6
3
7
11
30
24
0
+0.3
Note 1) Screw hole for wiring to cabinet's grounding plate
Note 2) The grounding plate thickness is 1.6mm
A B C Enclosed fittings L
AERSBAN-DSET 100 86 30 Two clamp fittings A Clamp fitting A 70
AERSBAN-ESET 70 56
One clamp fitting B Clamp fitting B 45