Mitsubishi Electronics C6/C64 Life Jacket User Manual


 
2. EXPLANATION OF MODULE FUNCTIONS
2.8 HR865 Card
II - 14
[Explanation of settings]
MODE
: Mode setting switch
Set the unit's operation state (Default setting: 0)
Master station Local station
0 : Online (remote net mode) Possible Possible
1 : Online (remote I/O net mode) Possible Not possible
2 : Offline Possible Possible
3 : Line test 1 Possible Not possible
4 : Line test 2 Possible Not possible
5 : Parameter confirmation test Possible Not possible
6 : Hardware test Possible Possible
7 to F: Not usable
STATION NO.
: Station number setting switch
Set the unit's station No. (Default setting: 0)
During remote net mode
Master station: 0
Local station: 1 to 64
Standby master station: 1 to 64
(If a value other than 0 to 64 is set, the "SW" and "L ERR." LEDs will light.)
During remote I/O net mode
Master station: 1 to 64 (set station number of final remote I/O station)
(If 0 is set, the "PLM" LED will light.)
B RATE
: Transmission speed setting switch
Set the unit's transmission speed. (Default setting: 0)
0 : 156kbps
1 : 625kbps
2 : 2.5Mbps
3 : 5Mbps
4 : 10Mbps
5 to 9 : Setting error ("SW" and "L ERR." LEDs light)
DIPSW (SW5) : Condition setting switch
Set the operation conditions (Default setting: All OFF)
SW1 Station type OFF: Master station/local station
ON: Standby master station
SW2 Use not possible Always OFF
SW3 Use not possible Always OFF
SW4 State of input data in OFF: Clear
data link error station ON: Hold
SW5, 6 Number of occupied stations SW5 SW6
OFF OFF : Station 1
OFF ON : Station 2
ON ON : Station 3
ON OFF : Station 4
SW7 Use not possible Always OFF