6. CONNECTION OF REMOTE I/O UNIT
6.9 Connection of FCUA-DX10/13/14 Unit and Machine Control Signal
I - 64
6.9 Connection of FCUA-DX10 /13 /14 Unit and Machine Control Signal
Input Output
Type of machine input/output
signal and No. of points
32 points 32 points
DO-L
R300 cable/
R301 cable
DI-L
R300 cable/
R301 cable
Machine
signal
FCUA-DX10
or
FCUA-DX13
or
FCUA-DX14
Machine
signal
The remote I/O unit cable types include the R300 and R301 cables. The R300 cable has one end cut off,
and the R301 cable is used for connection to the Izumi Denki terminal block BX1F-T40A (Note 1). The
R300-3M and R301-3M cables are available. If a cable longer than 3m is required, use the CN300 and
CS301 connector set.
The CN300 connector set (optional, with one end) includes the DI-L and DO-L connectors. The CS301
connector set (optional, with both ends) includes the DI-L and DO-L connectors, and two connectors for
connection with the terminal block (Izumi Denki).
(Note 1) Izumi Denki I/O terminal BX1F-T40
<Outline of connection>
24VDC(+)
24VDC(+)
Machine
control panel
DI-L
FCUA-DX100/130/140
COM
A
3
B3
B1
B2
A
1
A
2
B1
B2
A
1
A
2
2.2k
Input circuit
sink type
Output circuit
sink type
DO-L
0V
RA
PL
Control
circuit
Stabilized
power supply
DCIN
24VDC(+) 0V FG
1 2 3
RIO2
RIO1
FG
24VDC(+)
DI-L
FCUA-DX101/131/141
COM
A
3
B3
B1
B2
A
1
A
2
B1
B2
A
1
A
2
2.2k
Input circuit
source type
Output circuit
source type
DO-L
0V
RA
PL
DCIN
24VDC(+) 0V FG
1 2 3
RIO2
RIO1
FG
0V
Machine
control panel
Control
circuit
Stabilized
power supply
CAUTION
Incorrect connections could damage the device, so always connect the cable to the
designated connector.
Do not connect or disconnect the connection cables between each unit while the power
is ON.