APPENDIX 7 CABLE MANUFACTURING DRAWINGS
Appendix 7.6 F340 Cable Manufacturing Drawing
I - 91
Appendix 7.6 F340 Cable Manufacturing Drawing
Application : External skip signal input (4 points)
List of parts used
F340
Note (2)
1 2
3
5
Cotrol
unit side
Skip signal input
4
SKIP
F340
Assembly drawing
No. Part name/type Maker Q'ty
1
Connector
CDE-9PF
Hirose
Electric
1
2
Contact
CD-PC-111
Hirose
Electric
8
3
Connector case
HDE-CTH
Hirose
Electric
1
4
Wire material
B-22(19)X2SJ-1X9
Sumitomo
Denko
(4)
5
Crimp terminal
V1.25-4
J. S. T 8
Maximum cable length: 30m
Skip signal input
Control
unit side
1
6
2
7
3
8
4
9
Case GND plate
SKIP0
SKIP0*
SKIP1
SKIP1*
SKIP2
SKIP2*
SKIP3
SKIP3*
SKIP0
SKIP0*
SKIP1
SKIP1*
SKIP2
SKIP2*
SKIP3
SKIP3*
Connection diagram
Manufacturing precautions
(1) The parts used shall be Mitsubishi recommended parts. Equivalent parts may be used providing
they are compatible with the specifications.
(2) Attach the nameplate (with protective cover stamped with the cable name) in the position
designated in the assembly drawing.
(3) Fold the wire material shield on the control unit side over the sheath, and wrap copper foil tape
over it. Connect to the connector case GND plate.
(4) Stamp the name of each signal on the crimp terminal side mark tube and install.