6. CONNECTION OF REMOTE I/O UNIT
6.1 Outline of Remote I/O Unit
I - 55
6. CONNECTION OF REMOTE I/O UNIT
This chapter describes the connection between remote I/O unit and machine control signals.
6.1 Outline of Remote I/O Unit
The following ten types of remote I/O units (FCUA-DX ) are available, depending on the type of
input/output signal and No.of contacts. Use serial link connections (MC link B) to connect the unit with
the control unit or the communication terminal.
When the remote I/O unit is connected with serial links, multiple units can be used as long as the total
No. of occupied stations (channels) is within 8 stations. (Refer to Section 6.3 "Setting the Station No.
When Using Multiple Remote I/O Units" for details.)
Unit name Machine control signals that can be handled
No. of occupied
serial link stations
FCUA-DX100
Digital input signal (DI) : 32 points (insulation) sink/source type
Digital output signal (DO) : 32 points (non-insulation) sink type
1
FCUA-DX101
Digital input signal (DI) : 32 points (insulation) sink/source type
Digital output signal (DO) : 32 points (non-insulation) source type
1
FCUA-DX110
Digital input signal (DI) : 64 points (insulation) sink/source type
Digital output signal (DO) : 48 points (non-insulation) sink type
2
FCUA-DX111
Digital input signal (DI) : 64 points (insulation) sink/source type
Digital output signal (DO) : 48 points (non-insulation) source type
2
FCUA-DX120
Digital input signal (DI) : 64 points (insulation) sink/source type
Digital output signal (DO) : 48 points (non-insulation) sink type
Analog output (AO) : 1 point
2
FCUA-DX121
Digital input signal (DI) : 64 points (insulation) sink/source type
Digital output signal (DO) : 48 points (non-insulation) source type
Analog output (AO) : 1 point
2
FCUA-DX130
Digital input signal (DI) : 32 points (insulation) sink/source type
Digital output signal (DO) : 32 points (non-insulation) sink type
Handle input : 2 points
2
FCUA-DX131
Digital input signal (DI) : 32 points (insulation) sink/source type
Digital output signal (DO) : 32 points (non-insulation) source type
Handle input : 2 points
2
FCUA-DX140
Digital input signal (DI) : 32 points (insulation) sink/source type
Digital output signal (DO) : 32 points (non-insulation) sink type
Analog input (AI) : 4 points
Analog output (AO) : 1 point
2
FCUA-DX141
Digital input signal (DI) : 32 points (insulation) sink/source type
Digital output signal (DO) : 32 points (non-insulation) source type
Analog input (AI) : 4 points
Analog output (AO) : 1 point
2