APPENDIX 7 CABLE MANUFACTURING DRAWINGS
Appendix 7.8 F351 Cable Manufacturing Drawing
I - 93
Appendix 7.8 F351 Cable Manufacturing Drawing
Application : Extension DIO - machine electric cabinet
List of parts used
No. Part name/type Maker Q'ty
1
Connector
7940-6500SC
Sumitomo 3M 1
2
Strain relief
3448-7940
Sumitomo 3M 1
3
Wire material
B40-S
Note (1) (1)
1
2
First wire is colored
3 Machine power
distribution panel side
Maximum cable length: 50m
F351
Note (2)
Control unit side
Assembly drawing
Manufacturing precautions
(1) The parts used shall be Mitsubishi recommended parts. Equivalent parts may be used providing
they are compatible with the specifications.
(2) Attach the nameplate (with protective cover stamped with the cable name) in the position
designated in the assembly drawing.
(3) The DI and DO cables are the same. Stamp DI or DO on the connector to prevent incorrect
insertion.