6. CONNECTION OF REMOTE I/O UNIT
6.8 Outline of Analog Signal Input Circuit
I - 63
6.8 Outline of Analog Signal Input Circuit
The analog signal input circuit can be used only for the FCUA-DX140/DX141.
Input circuit
A
DC
150Ω
A
I
A
I*
Input conditions
Max. input rating
±15V
Resolution 10V/2000 (5mV)
Precision
Within ±25mV